Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1007426
Status: Active
Facility Name: Grand Prix #5152
Address: 7997 Forest Hills Rd.
Loves Park, IL 61111
County: Winnebago
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001269
Green Tag Issue Date: 3/9/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: GPM Midwest, LLC
Owner Address: 8565 Magellan Pkwy, Ste. 400
Richmond, VA 23227
Owner Status: Current Owner
Purchase Date: 3/18/2015
Type of Financial Responsibility: Surety Bond
Financial Responsibility Reporting Due Date: 4/24/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/9/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037728 GPM Midwest, LLC Current Owner 3/18/2015
U0033990 Road Ranger, LLC Former Owner 2/1/2007
U0029627 Selex, LLC Former Owner 7/1/2000
U0004916 Exel Sales Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-1862 9/29/2000 Removal Log 01631-2000REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
00-1314 Returned 9/9/2002 10/1/2002 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/29/2000
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/29/2000
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/29/2000
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 20000 Petroleum Use: None
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/12/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 10/19/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/20/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/10/2024 12/10/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 12/10/2024 12/10/2025
Overfill Prev Device Overfill Alarm 12/10/2024 12/10/2027
Overfill Prev Device Overfill Drop Tube Valve 12/10/2024 12/10/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/18/2024 3/18/2027
Leak Detect - Piping Sump Sensor 12/10/2024 12/10/2025
Spill Contain Device Single Wall Spill Bucket 12/10/2024 12/10/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/10/2024



Tank Number 5

Capacity: 15000 Petroleum Use: None
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/12/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 10/19/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/20/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/10/2024 12/10/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 12/10/2024 12/10/2025
Overfill Prev Device Overfill Alarm 12/10/2024 12/10/2027
Overfill Prev Device Overfill Drop Tube Valve 12/10/2024 12/10/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/18/2024 3/18/2027
Leak Detect - Piping Sump Sensor 12/10/2024 12/10/2025
Spill Contain Device Single Wall Spill Bucket 12/10/2024 12/10/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/10/2024



Tank Number 6

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/12/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 10/19/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/20/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/10/2024 12/10/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 12/10/2024 12/10/2025
Overfill Prev Device Overfill Alarm 12/10/2024 12/10/2027
Overfill Prev Device Overfill Drop Tube Valve 12/10/2024 12/10/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/18/2024 3/18/2027
Leak Detect - Piping Sump Sensor 12/10/2024 12/10/2025
Spill Contain Device Single Wall Spill Bucket 12/10/2024 12/10/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/10/2024



Tank Number 7

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 9/29/2000
OSFM First Notify Date: 10/3/2000 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 1/1/1976 Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 300 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/29/2000
OSFM First Notify Date: 10/3/2000 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 1/1/1976 Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found