Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1006050
Status: Active
Facility Name: Jay Maadi, Inc. d/b/a Clark Station
Address: 391 S. Main Street Seneca, IL 61360
County: LaSalle
Property Parcel: 24-26-214-013
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00691
Green Tag Issue Date: 1/15/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Peterson, Thomas and Bonnie
Owner Address: P.O. Box 994 Seneca, IL 61360
Owner Status: Current Owner
Purchase Date: 1/17/1978
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 8/12/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/15/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038952 Peterson, Thomas and Bonnie Current Owner 1/17/1978
U0037527 Jay Maadi, Inc. Former Owner 10/15/2014
U0031511 Patel, Gandabhai Former Owner 8/15/2003
U0029789 Clark Retail Enterprises, Inc. Former Owner 3/7/2001
U0015990 Wareco Service Inc Former Owner 2/22/1999

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
14-0289 4/15/2014 Abandonment Log 00239-2014ABN
19-0341 4/12/2019 Removal Log 01445-2018REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
14-0289 Eligible 4/21/2014 5/16/2014 $5,000
20140289 Eligible 10/17/2017 10/18/2017 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/12/2019
OSFM First Notify Date: 12/26/1985 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 12/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 11/7/2013 11/7/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/20/2018 12/20/2019
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 12/20/2018 12/20/2019
Overfill Prev Device Overfill Drop Tube Valve 12/20/2018 12/20/2021
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/20/2018 12/20/2021
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/12/2019
OSFM First Notify Date: 12/26/1985 Abandoned Material: Inert material mixed with portland cement
Current Age: 40 Abandoned Date: 4/15/2014
Install Date: 12/1/1978 Red Tag Issue Date:
Last Used Date: 11/7/2013 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 7/30/2008 7/30/2013
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/22/2012 10/22/2013
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/3/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/5/2025 8/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 8/5/2025 8/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/5/2025 8/5/2026
Overfill Prev Device Overfill Drop Tube Valve 8/5/2025 8/5/2028
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 8/5/2025 8/5/2028
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 8/3/2022 8/3/2023
Leak Detect - Piping Sump Sensor with positive shutdown 8/5/2025 8/5/2026
Spill Contain Device Double Wall Spill Bucket 8/5/2025 8/5/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 8/5/2025



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/3/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/5/2025 8/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 8/5/2025 8/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/5/2025 8/5/2026
Overfill Prev Device Overfill Drop Tube Valve 8/5/2025 8/5/2028
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 8/5/2025 8/5/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/5/2025 8/5/2026
Spill Contain Device Double Wall Spill Bucket 8/5/2025 8/5/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 8/5/2025



Tank Number 5

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/3/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/5/2025 8/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 8/5/2025 8/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/5/2025 8/5/2026
Overfill Prev Device Overfill Drop Tube Valve 8/5/2025 8/5/2028
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 8/5/2025 8/5/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/5/2025 8/5/2026
Spill Contain Device Double Wall Spill Bucket 8/5/2025 8/5/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 8/5/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/5/2025 8/5/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/5/2025 8/5/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/5/2025 8/5/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/5/2025 8/5/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/5/2025 8/5/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/5/2025 8/5/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
1006050 Jay Maadi, Inc. d/b/a Clark Station Seneca 06/07/2019 Letter Form