Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1005080
Status: Active
Facility Name: Galena Station
Address: 9927 US Highway 20 West
Galena, IL 61036
County: Jo Daviess
Property Parcel: 06-500-288-40
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: Z000842
Green Tag Issue Date: 2/20/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Linus LLC
Owner Address: 9927 US Highway 20 West
Galena, IL 61036
Owner Status: Current Owner
Purchase Date: 6/4/2024
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 1/17/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/20/2024 12/31/2026
Unattended Self Service 2/20/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041390 Linus LLC Current Owner 6/4/2024
U0035592 WSG, Incorporated Former Owner 10/1/2009
U0014314 Ron Sproule Oil Company Former Owner 11/1/1983
U0005586 Galena General Store Inc Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00142-2025CAT Cathodic Protection Approved / Issued 2/7/2025 2/7/2025 8/7/2025 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
12-1155 Eligible 1/17/2013 1/30/2013 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/24/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 11/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 4/11/2025 4/11/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2024 10/30/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 10/30/2024 10/30/2025
Overfill Prev Device Overfill Alarm 10/30/2024 10/30/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 10/30/2024 10/30/2025
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/23/2021



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/24/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 11/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 4/11/2025 4/11/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2024 10/30/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 10/30/2024 10/30/2025
Overfill Prev Device Overfill Alarm 10/30/2024 10/30/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 10/30/2024 10/30/2025
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/23/2021



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/24/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 11/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 4/11/2025 4/11/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2024 10/30/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 10/30/2024 10/30/2025
Overfill Prev Device Overfill Alarm 10/30/2024 10/30/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 10/30/2024 10/30/2025
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/23/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 10/30/2024 10/30/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 10/30/2024 10/30/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 10/30/2024 10/30/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 10/30/2024 10/30/2025

MFD Motorfuel Dispensing Forms

No Forms Found