Division of Petroleum & Chemical Safety

 

Facility: 2012966 Tank: 9

Click for Facility/Tank Ownership history

Capacity: 2000
Product: E85
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 12/30/2008
Current Age: 16
Install Date: 11/19/2008
Last Used Date:
Product Date: 12/8/2008
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/30/2024 7/30/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/30/2024 7/30/2025
Overfill Prev Device Overfill Drop Tube Valve 8/15/2023 8/15/2026
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 2/11/2025 2/11/2025 2/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/30/2024 7/30/2025
Spill Contain Device Double Wall Spill Bucket 2/11/2025 2/11/2025 2/11/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Latest Blended Fuel Compatibility Form

File Name Status Status Date
CompatibilityFormSummary01282025-070547.pdf Approved 2/15/2025

Compatibility Form Attachments

File Name Description
Veeder Root Mag Probes for Alternative Fluids.pdf ATG Probe
Veeder Root Mag Probes for Alternative Fluids.pdf ATG Probe
OPW-MH18037 Breakaway Coupling.pdf Breakaway
OPW-MH18037 Breakaway Coupling.pdf Breakaway
Modern Welding -E-85-BioFuels Compatibility 2018.pdf Composite Double Wall
Modern Welding -E-85-BioFuels Compatibility 2018.pdf Composite Double Wall
Veeder+Root+Sensor+Compatibility+Statement.pdf Dispenser # 15 Sensor
Veeder+Root+Sensor+Compatibility+Statement.pdf Dispenser # 15 Sensor
Franklin Fueling Compatability Listing - FS-0691 UL 2447 Listed Products.pdf Double Wall Spill Bucket
Veeder Root PLLD_DPLLD Fuel Compatibility.pdf Electronic Pressurized Line Leak Detection
FE Petro Submersible-E-85 & Biofuel compatible.pdf F.E. Petro AG Submersible Pump
FE Petro Submersible-E-85 & Biofuel compatible.pdf F.E. Petro AG Submersible Pump
NOV-Fiberglass Systems.pdf Fiberglass Double Wall
NOV-Fiberglass Systems.pdf Fiberglass Double Wall
Gasoila® E-Seal Technical Data.pdf Gasolia E-Seal
Gasoila® E-Seal Technical Data.pdf Gasolia E-Seal
Continental E25 E85 Hose Spec and Installation Instructions.pdf Hoses
Continental E25 E85 Hose Spec and Installation Instructions.pdf Hoses
OPW-MH1942-FLAMMABLE LIQUID HOSE NOZZLE VALVES _ UL Product iQ.pdf Nozzles
OPW-MH1942-FLAMMABLE LIQUID HOSE NOZZLE VALVES _ UL Product iQ.pdf Nozzles
OPW-Fuel Compatibility Matrix (Below Ground).pdf OPW Shear Valves
OPW-Fuel Compatibility Matrix (Below Ground).pdf OPW Shear Valves
OPW-Fuel Compatibility Matrix (Below Ground).pdf Overfill Drop Tube Valve
OPW-Fuel Compatibility Matrix (Below Ground).pdf Overfill Drop Tube Valve
Veeder Root ATG Compatibility.pdf Pressurized Line Leak Detector
Veeder Root ATG Compatibility.pdf Pressurized Line Leak Detector
Bravo Sump Compatibility Statement.pdf Single Wall STP/Tanktop Sump
Veeder Root Sensor Compatibility Statement.pdf Sump Sensor with positive shutdown
OPW 61SALP-MA Fill Adaptor Compatibility.pdf Swivel Fill Adapter
Veeder+Root+Sensor+Compatibility+Statement.pdf Tank Interstitial Sensor
Veeder+Root+Sensor+Compatibility+Statement.pdf Tank Interstitial Sensor
OPW-Fuel Compatibility Matrix (Below Ground).pdf UDC Containment Sump
OPW-Fuel Compatibility Matrix (Below Ground).pdf UDC Containment Sump
Wayne Dispensers-Combined Certification & UL-Wayne.pdf Wayne Fueling Dispensers
Wayne Dispensers-Combined Certification & UL-Wayne.pdf Wayne Fueling Dispensers

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 2/17/2025 Show History