Division of Petroleum & Chemical Safety

 

Facility: 4002378 Tank: 12

Click for Facility/Tank Ownership history

Capacity: 20000
Product: B-99
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 1/16/2004
Current Age: 21
Install Date: 11/6/2003
Last Used Date:
Product Date: 12/16/2003
Petroleum Use: None
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Flexible Non-Corrosive 9/30/2003 N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive 9/30/2003 N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 11/25/2024 11/25/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/25/2024 11/25/2025
Overfill Prev Device Overfill Drop Tube Valve 5/8/2023 11/28/2023 11/28/2026
Piping Blending Sump 4/7/2025 4/7/2028
Leak Detect - Piping Sump Sensor 11/25/2024 11/25/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/7/2025 4/7/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump 4/7/2025 4/7/2028
Leak Detect - Piping Sump Sensor 11/25/2024 11/25/2025
Spill Contain Device Double Wall Spill Bucket 5/27/2025 5/27/2025 5/27/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Latest Blended Fuel Compatibility Form

File Name Status Status Date
CompatibilityFormSummary05232025-064358.pdf Approved 5/23/2025

Compatibility Form Attachments

File Name Description
VR Mag Plus Probe Biodiesel Compatibility Letter 9-2-22.pdf ATG Probe
VR Mag Plus Probe Biodiesel Compatibility Letter 9-2-22.pdf ATG Probe
PCI Sump Compatibility.pdf Blending Sump
PCI Sump Compatibility.pdf Blending Sump
OPW 71SO-410CB DROP TUBE.pdf Double Wall Spill Bucket
GORMAN RUPP.pdf European with No Test Req Suction
Xerxes Compatibility.pdf Fiberglass Double Wall
Xerxes Compatibility.pdf Fiberglass Double Wall
Dualoy 3000 LCX Data Sheet.pdf Flexible Double Wall
Dualoy 3000 LCX Data Sheet.pdf Flexible Double Wall
794380-304 Single Float for Sumps Can Be Used on Tanks per VR_B99 Compat.pdf Non-Discriminating Interstitial Monitoring Sensors
794380-304 Single Float for Sumps Can Be Used on Tanks per VR_B99 Compat.pdf Non-Discriminating Interstitial Monitoring Sensors
Non Descriminating Leak Sensor 794380-321.pdf Non-Discriminating Sump Sensor in Blending Sump
Non Descriminating Leak Sensor 794380-321.pdf Non-Discriminating Sump Sensor in Blending Sump
DROP TUBE 71SO.pdf Overfill Drop Tube Valve
Non Descriminating Leak Sensor 794380-321.pdf Piping Sump Sensors Not Regulated in Single Wall STP/Tanktop Sump
Non Descriminating Leak Sensor 794380-321.pdf Piping Sump Sensors Not Regulated in Single Wall STP/Tanktop Sump
Xexes Biodiesel Compatibility Letter.pdf Single Wall STP/Tanktop Sump
Xexes Biodiesel Compatibility Letter.pdf Single Wall STP/Tanktop Sump
OPW SINGLE WALL SUMP.pdf Single Wall Transition Sump
OPW 1C-3112D.pdf Single Wall UDC Sump
Gorman Rupp Bio Pump.pdf Suction Pump
Gorman Rupp Bio Pump.pdf Suction Pump
SUMP SENSOR POSITIVE SHUT DOWN.pdf Sump Sensor in Blending Sump

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Flexible Double Wall Precision Test (Piping) Pass 4/7/2020 Show History
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 9/30/2020 Show History
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 8/18/2009 Show History