Division of Petroleum & Chemical Safety

 

Facility: 2020949 Tank: 9

Click for Facility/Tank Ownership history

Capacity: 6000
Product: E15
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 1/3/2017
Current Age: 8
Install Date: 9/29/2016
Last Used Date:
Product Date:
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/6/2023 10/8/2024 10/8/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/8/2024 10/8/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/6/2023 10/8/2024 10/8/2025
Overfill Prev Device Overfill Drop Tube Valve 12/6/2023 12/6/2023 12/6/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/16/2019 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 12/6/2023 10/8/2024 10/8/2025
Spill Contain Device Single Wall Spill Bucket 11/29/2022 11/29/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Latest Blended Fuel Compatibility Form

File Name Status Status Date
CompatibilityFormSummary12092023-075751.pdf Approved 2/12/2024

Compatibility Form Attachments

File Name Description
Veeder Root-577013-054 Mag Probes for Alternative Fluids.pdf ATG Probe
wayne dispensers all-Certificate of Compliance-03012019.pdf Dispenser
Veeder Root Compatibility.pdf Electronic Pressurized Line Leak Detection
Xerxes E-10 - E-100.pdf Fiberglass Double Wall
NOV_Compatibility of Red Thread IIA and Dualoy Piping Products.pdf Fiberglass Double Wall
OPW-Fuel Compatibility Matrix (Below Ground).pdf Fill Adapter
Continental E25 E85 Hose Spec and Installation Instructions.pdf Hose
Veeder+Root+Sensor+Compatibility+Statement.pdf Non-Discriminating Interstitial Monitoring Sensors
OPW-Fuel Compatibility Matrix (Above Ground).pdf Nozzle
OPW-Fuel Compatibility Matrix (Below Ground).pdf Overfill Drop Tube Valve
Gasoila® E-Seal Technical Data.pdf Pipe Dope
OPW E85 Compatiblity for Sheetz Site.pdf Shear Valve
Defender Spill Bucket E-15-E85 Compatibility.pdf Single Wall Spill Bucket
Bravo Fiberglass Sumps.pdf Single Wall STP/Tanktop Sump
Bravo Fiberglass Sumps.pdf Single Wall UDC Sump
FE Petro Products with Alt Fuels.pdf Submersible Turbine Pump
Veeder+Root+Sensor+Compatibility+Statement.pdf Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump
OPW-Fuel Compatibility Matrix (Below Ground).pdf Vapor Adapter

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/8/2024 Show History
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 12/6/2023 Show History