Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7047086
Status: Active
Facility Name: Love's Travel Stop #880
Address: 1503 South West St. Olney, IL 62450
County: Richland
Property Parcel: 11-10-101-103
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001701
Green Tag Issue Date: 1/26/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Love's Travel Stops & Country Stores, Inc.
Owner Address: 10601 N. Penn P.O. Box 26210 Oklahoma City, OK 73120
Owner Status: Current Owner
Purchase Date: 1/1/2020
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030965 Love's Travel Stops & Country Stores, Inc. Current Owner 1/1/2020

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261749 (Pending)    Issue Date: 7/8/2026    Expiration Date: 9/6/2026    View NOV Form

Tanks Violations
2 Spill prevention equipment failed triennial testing. Must be repaired or replaced. - Tank #2 Prem. Spill Bucket Remote fill failed testing 6/18/2026
2 Tank interstitial sensors in alarm or failed test, must repair or replace. - Tank #2 Prem. interstitial sensor is on.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: E15 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/2020 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2025 10/30/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2025 10/30/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/30/2025 10/30/2026
Overfill Prev Device Overfill Alarm 11/16/2023 11/16/2026
Overfill Prev Device Overfill Drop Tube Valve 11/16/2023 11/16/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2026 6/18/2029
Spill Contain Device Single Wall Spill Bucket 6/18/2026 6/18/2029
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 12/3/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 12/3/2020



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/2020 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2025 10/30/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/30/2025 10/30/2026
Overfill Prev Device Overfill Alarm 11/16/2023 11/16/2026
Overfill Prev Device Overfill Drop Tube Valve 11/16/2023 11/16/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2026 6/18/2029
Spill Contain Device Double Wall Spill Bucket Remote Fill 7/26/2023 6/18/2026
Spill Contain Device Single Wall Spill Bucket 6/18/2026 6/18/2029
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 12/3/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 12/3/2020



Tank Number 3

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/2020 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2025 10/30/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/30/2025 10/30/2026
Overfill Prev Device Overfill Alarm 11/16/2023 11/16/2026
Overfill Prev Device Overfill Drop Tube Valve 11/16/2023 11/16/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2026 6/18/2029
Piping Single Wall Transition Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2026 6/18/2029
Spill Contain Device Single Wall Spill Bucket 6/18/2026 6/18/2029
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 12/3/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 12/3/2020



Tank Number 4

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/2020 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2025 10/30/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/30/2025 10/30/2026
Overfill Prev Device Overfill Alarm 11/16/2023 11/16/2026
Overfill Prev Device Overfill Drop Tube Valve 11/16/2023 11/16/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2026 6/18/2029
Piping Single Wall Transition Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2026 6/18/2029
Spill Contain Device Single Wall Spill Bucket 6/18/2026 6/18/2029
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 12/3/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 12/3/2020



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/2020 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2025 10/30/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/30/2025 10/30/2026
Overfill Prev Device Overfill Alarm 11/16/2023 11/16/2026
Overfill Prev Device Overfill Drop Tube Valve 11/16/2023 11/16/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2026 6/18/2029
Spill Contain Device Single Wall Spill Bucket 6/18/2026 6/18/2029
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 10/30/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 12/3/2020

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 17/18SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 17SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 18/19SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 19/20SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 20/21SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 21

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/18/2026 6/18/2029
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
7047086 Love's Travel Stop #880 Olney 11/17/2020 Letter Form
7047086 Love's Travel Stop #880 Olney 07/22/2020 Letter Form