Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
7043372
Status:
Closed
Facility Name:
ABC Self Storage, LLC
Address:
500 South 10th Street Mount Vernon, IL 62864
County:
Jefferson
Property Parcel:
07-32-109-006
Facility Type:
Attended Self-Service/Unattended Self-Service
Owner Type:
Private
Green Tag Decal:
S001978
Green Tag Issue Date:
5/18/2017
Green Tag Expiration Date:
12/31/2019
Owner Details
Owner Name:
ABC Self Storage, LLC
Owner Address:
2408 South 10th Street Mount Vernon, IL 62864
Owner Status:
Current Owner
Purchase Date:
10/6/2021
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
3/13/2019
12/31/2021
Unattended Self Service
3/13/2019
12/31/2021
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0041301
ABC Self Storage, LLC
Current Owner
10/6/2021
U0033642
ABC Self Storage LLC
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
N/A
3/12/2025
Removal Log
01180-2024REM
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
15000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
3/12/2025
OSFM
First Notify Date:
4/2/2007
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
12/1/2006
Red Tag Issue Date:
Last Used Date:
9/26/2019
Fee Due:
$0.00
Product Date:
3/20/2007
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
3/24/2017
3/24/2020
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/29/2019
4/29/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
4/29/2019
4/29/2020
Overfill Prev Device
Overfill Drop Tube Valve
4/29/2019
4/29/2022
Piping
Fiberglass Double Wall Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
4/29/2019
4/29/2022
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
5000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
3/12/2025
OSFM
First Notify Date:
4/2/2007
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
12/1/2006
Red Tag Issue Date:
Last Used Date:
5/14/2019
Fee Due:
$0.00
Product Date:
3/20/2007
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
3/24/2017
3/24/2020
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/29/2019
4/29/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
4/29/2019
4/29/2020
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Double Wall Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
4000
Petroleum Use:
Product:
E85
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
3/12/2025
OSFM
First Notify Date:
4/2/2007
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
12/1/2006
Red Tag Issue Date:
Last Used Date:
5/14/2019
Fee Due:
$0.00
Product Date:
3/20/2007
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
3/24/2017
3/24/2020
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/29/2019
4/29/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
4/29/2019
4/29/2020
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Double Wall Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
4/29/2019
4/29/2022
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
5000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
3/12/2025
OSFM
First Notify Date:
4/2/2007
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
12/1/2006
Red Tag Issue Date:
Last Used Date:
9/26/2019
Fee Due:
$0.00
Product Date:
3/20/2007
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
3/24/2017
3/24/2020
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/29/2019
4/29/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
4/29/2019
4/29/2020
Overfill Prev Device
Overfill Drop Tube Valve
4/29/2019
4/29/2022
Piping
Fiberglass Double Wall Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
4/29/2019
4/29/2022
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found