Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7042092
Status: Active
Facility Name: Love's Travel Stop #318
Address: 202 North Ave. Ina, IL 62846
County: Jefferson
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01107
Green Tag Issue Date: 8/5/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Love's Travel Stops & Country Stores, Inc.
Owner Address: 10601 N. Penn P.O. Box 26210 Oklahoma City, OK 73120
Owner Status: Current Owner
Purchase Date: 4/10/2015
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/5/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030965 Love's Travel Stops & Country Stores, Inc. Current Owner 4/10/2015

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00402-2025UPG Upgrade Approved / Issued 4/3/2025 4/3/2025 10/3/2025 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/23/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/23/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/10/2025 2/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Alarm 10/26/2022 10/26/2025
Overfill Prev Device Overfill Drop Tube Valve 10/26/2022 10/26/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/24/2024 10/24/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 11/3/2020 11/3/2021
Leak Detect - Piping Non-Discriminating Sump Sensor 10/27/2021 10/27/2022
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Piping Single Wall Transition Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Spill Contain Device Single Wall Spill Bucket 10/24/2024 10/24/2027
Tank Composite Double Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 10/27/2021
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/27/2023



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/23/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/23/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 2/10/2025 2/10/2026
Overfill Prev Device Overfill Alarm 10/26/2022 10/26/2025
Overfill Prev Device Overfill Drop Tube Valve 10/26/2022 10/26/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/24/2024 10/24/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 10/27/2021 10/27/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/24/2024 10/24/2027
Tank Composite Double Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 3/17/2022



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/23/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/23/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/8/2025 4/8/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Alarm 10/26/2022 10/26/2025
Overfill Prev Device Overfill Drop Tube Valve 10/26/2022 10/26/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/24/2024 10/24/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 10/27/2021 10/27/2022
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Piping Single Wall Transition Sump 10/24/2024 10/24/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 10/27/2021 10/27/2022
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Spill Contain Device Single Wall Spill Bucket 10/24/2024 10/24/2027
Tank Composite Double Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 10/27/2021
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 4/5/2025



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/23/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/23/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Alarm 10/26/2022 10/26/2025
Overfill Prev Device Overfill Drop Tube Valve 10/26/2022 10/26/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025
Spill Contain Device Single Wall Spill Bucket 10/24/2024 10/24/2027
Tank Composite Double Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 10/27/2021



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/23/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/23/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/26/2024 9/26/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Alarm 10/26/2022 10/26/2025
Overfill Prev Device Overfill Drop Tube Valve 10/26/2022 10/26/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025
Spill Contain Device Single Wall Spill Bucket 10/24/2024 10/24/2027
Tank Composite Double Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 10/26/2022
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 9/27/2023



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/23/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/23/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/26/2024 9/26/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Alarm 10/26/2022 10/26/2025
Overfill Prev Device Overfill Drop Tube Valve 7/16/2025 7/16/2028
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025
Spill Contain Device Single Wall Spill Bucket 10/24/2024 10/24/2027
Tank Composite Double Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 10/26/2022
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 9/27/2023



Tank Number 7

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/10/2012 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 7/26/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/26/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/13/2025 2/13/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Alarm 10/26/2022 10/26/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/24/2024 10/24/2027
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 10/27/2021 10/27/2022
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Piping Single Wall Transition Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Piping Single Wall Transition Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Piping Single Wall Transition Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Spill Contain Device Single Wall Spill Bucket 10/24/2024 10/24/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 9/26/2024



Tank Number 8

Capacity: 12000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 9/10/2012 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 7/26/2012 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 7/26/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 11/12 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 13/14 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 15/16 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 17/18S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 2/10/2025 2/10/2026



Name\ID 17S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 18/19S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 2/10/2025 2/10/2026



Name\ID 19/20S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 20/21S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 21/22S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 22/23S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 3/4 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 5/6 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 7/8 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025



Name\ID 9/10 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/24/2024 10/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025

MFD Motorfuel Dispensing Forms

No Forms Found