Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7036383
Status: Active
Facility Name: Casey's General Stores #2053
Address: 202 S. Park Street Sesser, IL 62884
County: Franklin
Property Parcel: 01-13-184-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001090
Green Tag Issue Date: 10/16/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave. P.O. Box 3004 Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 4/28/1998
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/16/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 4/28/1998

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01465-2025UPG Upgrade Approved / Issued 10/31/2025 11/3/2025 5/5/2026 Documents
01237-2025CAT Cathodic Protection Approved / Issued 9/21/2025 9/22/2025 3/24/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020253027 (Pending)    Issue Date: 11/13/2025    Expiration Date: 1/12/2026    View NOV Form

Tanks Violations
1 Overfill prevention equipment inspection(s) not completed (Required every 3 years).

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/19/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 4/29/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/30/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/24/2025 9/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/24/2025 9/24/2026
Overfill Prev Device Overfill Drop Tube Valve 10/27/2022 10/27/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/20/2025 10/20/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/19/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 4/29/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/30/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/24/2025 9/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/24/2025 9/24/2026
Overfill Prev Device Overfill Drop Tube Valve 10/20/2025 10/20/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/20/2025 10/20/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found