Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7033883
Status: Active
Facility Name: Flamm Orchards, Inc.
Address: R. R. #2, Box 875 Cobden, IL 62920
County: Union
Property Parcel:
Facility Type: Farm
Owner Type: Private
Green Tag Decal: BB03861
Green Tag Issue Date: 2/6/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Fleet

Owner Details

Owner Name: Flamm Orchards, Inc.
Owner Address: 8760 Old Hwy 51 N Cobden, IL 62920
Owner Status: Current Owner
Purchase Date: 1/1/1978
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/13/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0023780 Flamm Orchards, Inc. Current Owner 1/1/1978

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 11/28/2012 Removal Log 01122-2012REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/28/2012
OSFM First Notify Date: 2/8/1995 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1978

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 1/13/2006 1/13/2011
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flex Connector Steel Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/28/2012
OSFM First Notify Date: 2/8/1995 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1980

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 1/13/2006 1/13/2011
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flex Connector Steel Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/7/2013 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 12/4/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/4/2012

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/1/2025 12/1/2026
Overfill Prev Device Overfill Drop Tube Valve 6/2/2023 6/2/2026
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated 10/6/2020 10/6/2023
Spill Contain Device Single Wall Spill Bucket 11/25/2024 11/25/2027
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 6/2/2023



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/7/2013 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 12/4/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/4/2012

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/1/2025 12/1/2026
Overfill Prev Device Overfill Drop Tube Valve 6/2/2023 6/2/2026
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated 10/6/2020 10/6/2023
Spill Contain Device Single Wall Spill Bucket 11/25/2024 11/25/2027
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 6/2/2023

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found