Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7029015
Status: Active
Facility Name: Golconda Marina
Address: State Route 146 North, PO Box 458 Golconda, IL 62938
County: Pope
Property Parcel:
Facility Type: Marina
Owner Type: State
Green Tag Decal: Z001093
Green Tag Issue Date: 10/31/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Marina

Owner Details

Owner Name: Illinois Department of Natural Resources
Owner Address: One Natural Resources Way Springfield, IL 62702
Owner Status: Current Owner / Operator
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 3/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0007261 Illinois Department of Natural Resources Current Owner / Operator

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261088 (Pending)    Issue Date: 4/22/2026    Expiration Date: 6/21/2026    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
2, 3 Annual leak detection certification not completed (Required annually).
3 Dispensers - hoses cracked, split or worn and require replacement
2, 3 Line interstitial sensor functional test not accomplished (Required annually).
2, 3 Mechanical line leak detector requires annual functional test.
Facility Missing copies of Annual Walkthrough Inspection Report.
2, 3 Tank interstitial sensor functional test not accomplished (Required annually).

NOV Number: E0020261089 (Pending)    Issue Date: 4/22/2026    Expiration Date: 6/21/2026    View NOV Form

Tanks Violations
Facility Nozzles at marinas shall not be equipped with hold-open devices

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/29/1998
OSFM First Notify Date: 12/24/1991 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 4/1/1988 Red Tag Issue Date:
Last Used Date: 8/22/1998 Fee Due: $0.00
Product Date: 4/15/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/6/1999 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 6/10/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/10/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/6/2025 3/6/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/6/2025 3/6/2026
Overfill Prev Device Overfill Drop Tube Valve 6/10/2025 6/10/2028
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 6/10/2025 6/10/2028
Leak Detect - Piping Sump Sensor 3/6/2025 3/6/2026
Piping Single Wall Transition Sump 6/10/2025 6/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/6/2025 3/6/2026
Spill Contain Device Single Wall Spill Bucket 6/10/2025 6/10/2028
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 3/6/2025



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/6/1999 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 6/10/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/10/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/6/2025 3/6/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/6/2025 3/6/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/6/2025 3/6/2026
Overfill Prev Device Overfill Drop Tube Valve 6/10/2025 6/10/2028
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 6/10/2025 6/10/2028
Leak Detect - Piping Sump Sensor 3/6/2025 3/6/2026
Piping Single Wall Transition Sump 6/10/2025 6/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/6/2025 3/6/2026
Spill Contain Device Single Wall Spill Bucket 6/10/2025 6/10/2028
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 3/6/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2025 6/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/6/2025 3/6/2026



Name\ID 3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2025 6/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/6/2025 3/6/2026



Name\ID 4/5

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2025 6/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/6/2025 3/6/2026

MFD Motorfuel Dispensing Forms

No Forms Found