Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7023246
Status: Closed
Facility Name: JT's Burgers & More
Address: 310 Joppa Road Joppa, IL 62953
County: Massac
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: N002553
Green Tag Issue Date: 4/24/2012
Green Tag Expire Date: 12/31/2014
MFD Type: N/A

Owner Details

Owner Name: Jennifer's Trucking, Inc.
Owner Address: 164 Knox Road Grand Chain, IL 62941
Owner Status: Current Owner
Purchase Date: 7/6/2013
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037075 Jennifer's Trucking, Inc. Current Owner 7/6/2013
U0034851 Godfrey, David Former Owner 6/26/2008
U0032729 Charles & Margaret Lewis Former Owner 2/9/2005
U0030870 Charles & Johnson, Robert & Charle Former Owner 6/20/2003
U0015667 Veach Oil Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
13-1157 11/14/2013 Removal Log 01108-2013REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
13-1157 Eligible 12/13/2013 1/2/2014 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/14/2013
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 2/17/1984 Red Tag Issue Date:
Last Used Date: 8/1/2012 Fee Due: $0.00
Product Date: 2/17/1984

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 7/1/2008 7/1/2013
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 3000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/14/2013
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: 8/1/2012 Fee Due: $0.00
Product Date: 1/1/1973

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 7/1/2008 7/1/2013
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/14/2013
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: 8/1/2012 Fee Due: $0.00
Product Date: 1/1/1973

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 7/1/2008 7/1/2013
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/14/2013
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 8/1/2012 Fee Due: $0.00
Product Date: 1/1/1971

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 7/1/2008 7/1/2013
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found