Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7023241
Status: Active
Facility Name: Hucks #111
Address: 102 West 10th Street Metropolis, IL 62960
County: Massac
Property Parcel: 08-01-196-015
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00610
Green Tag Issue Date: 3/5/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Martin & Bayley, Inc.
Owner Address: P.O. Box 385 Carmi, IL 62821
Owner Status: Current Owner
Purchase Date: 7/30/1996
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 12/24/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009763 Martin & Bayley, Inc. Current Owner 7/30/1996
U0015667 Veach Oil Company Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
96-1555 8/27/1996 Removal Log 0648-96

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
96-0583 Eligible 12/24/1996 1/24/1997 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/27/1996
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/26/1996 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/27/1996
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/26/1996 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/28/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 7/1/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1996

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/24/2026 8/24/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 8/24/2026 8/24/2027
Overfill Prev Device Overfill Drop Tube Valve 4/24/2026 4/24/2029
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 4/22/2026 4/22/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/22/2026 4/22/2029
Spill Contain Device Double Wall Spill Bucket 4/22/2026 4/22/2029
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 8/30/2021
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 8/24/2026
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 8/21/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/24/2026



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/28/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 7/1/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1996

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/24/2026 8/24/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 8/24/2026 8/24/2027
Overfill Prev Device Overfill Drop Tube Valve 4/24/2026 4/24/2029
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 4/22/2026 4/22/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/22/2026 4/22/2029
Spill Contain Device Double Wall Spill Bucket 4/22/2026 4/22/2029
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 9/2/2021
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 8/21/2025
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 8/24/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/24/2026



Tank Number 5

Capacity: 10000 Petroleum Use: Dispensing
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 7/22/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/22/2026

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/24/2026 8/24/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 8/24/2026 8/24/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/24/2026 8/24/2027
Overfill Prev Device Overfill Drop Tube Valve 4/24/2026 4/24/2029
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 2/5/2026 2/5/2029
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2026 2/5/2029
Spill Contain Device Double Wall Spill Bucket 2/5/2026 2/5/2029
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 8/24/2026
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 4/24/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/5/2026 2/5/2029
Leak Detect - Piping Sump Sensor with positive shutdown 8/24/2026 8/24/2027



Name\ID 1/2

Status: InActive

No Equipment Listed




Name\ID 3/4

Status: InActive

No Equipment Listed




Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/5/2026 2/5/2029
Leak Detect - Piping Sump Sensor with positive shutdown 8/24/2026 8/24/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/5/2026 2/5/2029
Leak Detect - Piping Sump Sensor with positive shutdown 8/24/2026 8/24/2027



Name\ID 5/6

Status: InActive

No Equipment Listed




Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/5/2026 2/5/2029
Leak Detect - Piping Sump Sensor with positive shutdown 8/24/2026 8/24/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/5/2026 2/5/2029
Leak Detect - Piping Sump Sensor with positive shutdown 8/24/2026 8/24/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
7023241 Hucks #111 Metropolis 04/22/2026 Letter Form
7023241 Hucks #111 Metropolis 12/15/2025 Letter Form
7023241 Hucks #111 Metropolis 07/16/2025 Letter Form