Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0003338 |
Consolidation Coal Company |
Current Owner |
10/20/1995 |
| U0007545 |
Inland Steel Coal Co |
Former Owner |
12/31/1967 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 92-0110 |
1/13/1992 |
Removal Log |
|
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Hydraulic Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
1/13/1992 |
|
OSFM
First Notify Date: |
5/8/1986 |
|
Abandoned Material: |
|
| Current Age: |
22 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1970 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
6/6/2006 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gear Lube |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
1/13/1992 |
|
OSFM
First Notify Date: |
5/8/1986 |
|
Abandoned Material: |
|
| Current Age: |
22 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1970 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
1/27/2011 |
|
OSFM
First Notify Date: |
3/1/1996 |
|
Abandoned Material: |
|
| Current Age: |
15 |
|
Abandoned Date: |
|
| Install Date: |
11/1/1995 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
8/12/2010 |
|
Fee Due: |
$0.00 |
| Product Date: |
11/28/1995 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
9/6/2009 |
9/6/2012 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Sump Sensor |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors
|
Sensor Functional
|
Pass
|
9/6/2009
|
|
Leak Detect - Piping
|
Sump Sensor
|
Sensor Functional
|
Pass
|
9/6/2009
|
Tank Number 4
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Hydraulic Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
1/26/2011 |
|
OSFM
First Notify Date: |
3/1/1996 |
|
Abandoned Material: |
|
| Current Age: |
15 |
|
Abandoned Date: |
|
| Install Date: |
11/1/1995 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
6/6/2006 |
|
Fee Due: |
$0.00 |
| Product Date: |
11/28/1995 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
No passing test found |
No passing test found |
|
Piping
|
Double Wall steel |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
|
|
CERCLA Substance: |
Solsenic B Oil |
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
1/26/2011 |
|
OSFM
First Notify Date: |
3/1/1996 |
|
Abandoned Material: |
|
| Current Age: |
15 |
|
Abandoned Date: |
|
| Install Date: |
11/1/1995 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
6/6/2006 |
|
Fee Due: |
$0.00 |
| Product Date: |
11/28/1995 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
No passing test found |
No passing test found |
|
Piping
|
Double Wall steel |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found