Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7021610
Status: Active
Facility Name: Metropolis Gas N Go LLC d/b/a DJ Mart 4
Address: 1117 E. 5th Street Metropolis, IL 62960
County: Massac
Property Parcel: 08-12-220-009
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: BB00613
Green Tag Issue Date: 3/10/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Self Service

Owner Details

Owner Name: A2 IL Investments, LLC
Owner Address: 113 W Green Street Centralia, IL 62801
Owner Status: Current Owner
Purchase Date: 11/19/2025
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/6/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041593 A2 IL Investments, LLC Current Owner 11/19/2025
U0040111 ARG KK10PCK001, LLC Former Owner 12/11/2020
U0008547 Knapp Oil Company, Inc. Former Owner 1/1/1971

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
14-1214 11/12/2014 Removal Log 01054-2014REM
99-2410 10/25/1999 Removal Log 02821-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
99-1949 Eligible 12/21/1999 12/23/1999 $10,000
14-1214 Eligible 2/20/2015 4/8/2015 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/12/2014
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 1/16/2014 Fee Due: $0.00
Product Date: 1/1/1971

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/20/2011 12/20/2014
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 10/7/2008 10/7/2013
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/7/2011 12/7/2012
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/12/2014
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 10/24/2014 Fee Due: $0.00
Product Date: 1/1/1974

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/20/2011 12/20/2014
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 1/16/2014 1/16/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/4/2013 12/4/2014
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/25/1999
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date: 1/1/1979

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/25/1999
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date: 1/1/1979

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/19/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/11/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/11/1999

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/28/2026 2/28/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/28/2026 2/28/2027
Overfill Prev Device Overfill Drop Tube Valve 12/11/2024 12/11/2027
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping STP/Tanktop Sump containment FRP 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/11/2024 12/11/2027
Spill Contain Device Single Wall Spill Bucket 12/11/2024 12/11/2027
Tank Composite Single Wall ACT 100 Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 12/10/2025



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/19/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 10/28/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/28/1999

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/10/2025 12/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 12/3/2025 12/3/2026
Overfill Prev Device Overfill Drop Tube Valve 12/11/2024 12/11/2027
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Not applicable Not applicable
Piping STP/Tanktop Sump containment FRP 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/11/2024 12/11/2027
Spill Contain Device Single Wall Spill Bucket 12/11/2024 12/11/2027
Tank Composite Single Wall ACT 100 Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 12/10/2025



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/29/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 11/19/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/20/2014

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/10/2025 12/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 12/10/2025 12/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/10/2025 12/10/2026
Overfill Prev Device Overfill Drop Tube Valve 12/11/2024 12/11/2027
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Not applicable Not applicable
Piping STP/Tanktop Sump containment FRP 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/11/2024 12/11/2027
Piping Single Wall Transition Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/11/2024 12/11/2027
Spill Contain Device Single Wall Spill Bucket 12/11/2024 12/11/2027
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 12/10/2025



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/29/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 11/19/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/20/2014

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/10/2025 12/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 12/10/2025 12/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/10/2025 12/10/2026
Overfill Prev Device Overfill Drop Tube Valve 12/11/2024 12/11/2027
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Not applicable Not applicable
Piping STP/Tanktop Sump containment FRP 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/11/2024 12/11/2027
Piping Single Wall Transition Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/11/2024 12/11/2027
Spill Contain Device Single Wall Spill Bucket 12/11/2024 12/11/2027
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 12/10/2025

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor 12/10/2025 12/10/2026



Name\ID 10 Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor 12/10/2025 12/10/2026



Name\ID 11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor 12/10/2025 12/10/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor 12/10/2025 12/10/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor 12/10/2025 12/10/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor 12/10/2025 12/10/2026



Name\ID 9 Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor 12/10/2025 12/10/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/11/2024 12/11/2027
Leak Detect - Piping Sump Sensor 12/10/2025 12/10/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found