Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7021606
Status: Active
Facility Name: KKG5, Inc. d/b/a Xenia Citgo
Address: 1500 Church St.
US 50 & Xenia Road
Xenia, IL 62899
County: Clay
Property Parcel: 13-03-100-007
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001764
Green Tag Issue Date: 6/25/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: ARG KK10PCK001, LLC
Owner Address: 38 Washington Square
Newport, RI 02840
Owner Status: Current Owner
Purchase Date: 12/11/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/3/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/25/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040111 ARG KK10PCK001, LLC Current Owner 12/11/2020
U0008547 Knapp Oil Company, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
04-1677 2/15/2005 Removal Log 05923-2005REM
17-1134 1/30/2018 Removal Log 01574-2017REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
04-1677 Eligible 12/16/2004 1/4/2005 $10,000
20171134 Eligible 2/22/2018 3/2/2018 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/30/2018
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/12/2012 9/12/2017
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Ground Water Monitoring Electronic
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/30/2018
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/12/2012 9/12/2017
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Ground Water Monitoring Electronic
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/15/2005
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 2/1/2005 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/14/2005 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 2/17/2005 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/17/2005

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 1/10/2025 1/10/2026
Overfill Prev Device Overfill Drop Tube Valve 1/10/2025 1/10/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/10/2025 1/10/2028
Tank Composite Single Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 11000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/23/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 2/13/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/13/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 1/10/2025 1/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/10/2025 1/10/2026
Overfill Prev Device Overfill Drop Tube Valve 1/10/2025 1/10/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/10/2025 1/10/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/23/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 2/13/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/13/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 1/10/2025 1/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/10/2025 1/10/2026
Overfill Prev Device Overfill Drop Tube Valve 1/10/2025 1/10/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/10/2025 1/10/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found