Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7021604
Status: Closed
Facility Name: Eldorado 76
Address: 1413 Highway 45 South Eldorado, IL 62930
County: Saline
Property Parcel:
Facility Type: Bulk Plant
Owner Type: Private
Green Tag Decal: N002516
Green Tag Issue Date: 8/23/2012
Green Tag Expire Date: 12/31/2014
MFD Type: N/A

Owner Details

Owner Name: Knapp Oil Company, Inc.
Owner Address: P.O. Box 215 Xenia, IL 62899
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0008547 Knapp Oil Company, Inc. Current Owner
U0008549 Knapp Oil Company, Inc. Former Owner 12/31/2013
U0008547 Knapp Oil Company, Inc. Former Owner 12/31/1967
U0021869 Rash, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
14-0949 9/12/2014 Abandonment Log 00805-2014ABN
N/A 3/16/2011 Removal Log 01139-2010REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
14-0949 Eligible 10/20/2014 12/16/2014 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/6/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 74 Abandoned Date: 9/12/2014
Install Date: 1/1/1952 Red Tag Issue Date:
Last Used Date: 11/26/2013 Fee Due: $0.00
Product Date: 1/1/1952

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Other Aboveground Piping Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 6/20/2008 6/20/2013
Leak Detect - Piping Aboveground Not applicable Not applicable
Leak Detect - Tank Ground Water Monitoring Electronic No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Aboveground Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 12000 Petroleum Use:
Product: 100% Soy Oil (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/7/2008 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Tank Ground Water Monitoring Wells No passing test found No passing test found

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/19/2007
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 7/1/2007 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal No passing test found No passing test found
Leak Detect - Piping Electronic Pressurized Line Leak Detection No passing test found No passing test found
Leak Detect - Tank Monthly Inv Ctrl and Prec Tight Testing No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Manhole Field Constructed No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 3000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/16/2011
OSFM First Notify Date: 6/20/1987 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/7/2008 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Tank Ground Water Monitoring Wells No passing test found No passing test found

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found