Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
7021604
Status:
Closed
Facility Name:
Eldorado 76
Address:
1413 Highway 45 South
Eldorado, IL 62930
County:
Saline
Property Parcel:
Facility Type:
Bulk Plant
Owner Type:
Private
Green Tag Decal:
N002516
Green Tag Issue Date:
8/23/2012
Green Tag Expiration Date:
12/31/2014
Owner Details
Owner Name:
Knapp Oil Company, Inc.
Owner Address:
P.O. Box 215
Xenia, IL 62899
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
8/13/2004
8/15/2005
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0008547
Knapp Oil Company, Inc.
Current Owner
U0008549
Knapp Oil Company, Inc.
Former Owner
12/31/2013
U0008547
Knapp Oil Company, Inc.
Former Owner
12/31/1967
U0021869
Rash, Inc.
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
14-0949
9/12/2014
Abandonment Log
00805-2014ABN
N/A
3/16/2011
Removal Log
01139-2010REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
14-0949
Eligible
10/20/2014
12/16/2014
$5,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
12000
Petroleum Use:
Product:
B-99
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/6/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
73
Abandoned Date:
9/12/2014
Install Date:
1/1/1952
Red Tag Issue Date:
Last Used Date:
11/26/2013
Fee Due:
$0.00
Product Date:
1/1/1952
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Other Aboveground Piping
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
6/20/2008
6/20/2013
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Ground Water Monitoring Electronic
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Aboveground
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
12000
Petroleum Use:
Product:
100% Soy Oil (Non-Regulated)
CERCLA Substance:
Status:
Unknown
CAS Code:
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
5/6/1986
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
1/7/2008
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Leak Detect - Tank
Ground Water Monitoring Wells
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/19/2007
OSFM
First Notify Date:
5/6/1986
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
7/1/2007
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
Leak Detect - Tank
Monthly Inv Ctrl and Prec Tight Testing
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
3000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
3/16/2011
OSFM
First Notify Date:
6/20/1987
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
1/7/2008
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Leak Detect - Tank
Ground Water Monitoring Wells
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found