Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7011186
Status: Closed
Facility Name: Pundrake
Address: 405 Fifth Street Carmi, IL 62821
County: White
Property Parcel: 13-13-164-008
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: W003765
Green Tag Issue Date: 9/8/2021
Green Tag Expiration Date: 12/31/2023

Owner Details

Owner Name: A & S Enterprises of Illinois, LLC
Owner Address: P.O. Box 221 Carmi, IL 62821
Owner Status: Current Owner
Purchase Date: 4/30/2004
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/6/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/24/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032077 A & S Enterprises of Illinois, LLC Current Owner 4/30/2004
U0030129 Robert J & Dorothy L. Williams Trust, Former Owner 7/1/1999
U0027783 Super Stop Inc Former Owner 4/4/1998
U0012223 Pud Williams Farms Inc Former Owner 12/31/1967
U0037217 Williams, Robert Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
13-1342 1/30/2014 Abandonment Log 01290-2013ABN
19-1051 11/15/2019 Abandonment Log 02070-2019ABN
2025-0060 1/30/2025 Removal Log 01458-2024REM
2025-0060 1/29/2025 Abandonment Log 01474-2024ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
13-1342 Eligible 2/14/2014 2/26/2014 $5,000
20191051 Eligible 11/8/2019 11/18/2019 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/30/2025
OSFM First Notify Date: 5/15/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 42 Abandoned Date: 11/15/2019
Install Date: 10/1/1982 Red Tag Issue Date:
Last Used Date: 8/8/2018 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 4/24/2018 4/24/2019
Corrosion Prot - Tank Impressed Current Cathodic Protection 4/24/2018 4/24/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/15/2018 5/15/2019
Leak Detect - Tank Automatic Tank Gauging Incon TS 750
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/30/2025
OSFM First Notify Date: 5/15/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 42 Abandoned Date: 1/30/2014
Install Date: 10/1/1982 Red Tag Issue Date:
Last Used Date: 10/1/2009 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/16/2007 10/16/2008
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/16/2007 10/16/2008
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/19/2009 5/19/2010
Leak Detect - Tank Monthly Inv Ctrl and Prec Tight Testing 5/19/2009 5/19/2010
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/15/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 42 Abandoned Date: 1/29/2025
Install Date: 10/1/1982 Red Tag Issue Date:
Last Used Date: 12/4/2023 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/3/2023 6/3/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 6/3/2023 6/3/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2023 6/3/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2023 6/3/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 6/3/2023 6/3/2024
Overfill Prev Device Overfill Drop Tube Valve 5/28/2021 5/28/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/28/2021 5/28/2024
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/3/2023



Tank Number 4

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/15/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 42 Abandoned Date: 1/29/2025
Install Date: 10/1/1982 Red Tag Issue Date:
Last Used Date: 12/4/2023 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/3/2023 6/3/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 6/3/2023 6/3/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2023 6/3/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 6/3/2023 6/3/2024
Overfill Prev Device Overfill Drop Tube Valve 5/28/2021 5/28/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/28/2021 5/28/2024
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/3/2023



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/16/2001
OSFM First Notify Date: 10/13/1998 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 10/1/1987 Red Tag Issue Date:
Last Used Date: 10/30/2000 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 1000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/30/2025
OSFM First Notify Date: 11/29/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 10/17/2001 Red Tag Issue Date:
Last Used Date: 12/4/2023 Fee Due: $0.00
Product Date: 10/17/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/3/2023 6/3/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 6/3/2023 6/3/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/10/2022 6/10/2023
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 7/29/2021 6/10/2022
Overfill Prev Device Overfill Drop Tube Valve 5/28/2021 5/28/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/28/2021 5/28/2024
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/10/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID K-1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found