Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7008359
Status: Active
Facility Name: The Cupboard
Address: 14967 Highway 4 Campbell Hill, IL 62916
County: Jackson
Property Parcel: 02-09-327-012
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z003672
Green Tag Issue Date: 6/18/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Windy Hill Holdings LLC
Owner Address: 71 Reiman Road Campbell Hill, IL 62916
Owner Status: Current Owner
Purchase Date: 8/6/2025
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/9/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 11/14/2024 12/31/2026
Self Service 6/18/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041633 Windy Hill Holdings LLC Current Owner 8/6/2025
U0023788 Lampe , Carl Former Owner 11/1/1994
U0016742 Yesley Service Co., Inc. Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252719 (Pending)    Issue Date: 10/8/2025    Expiration Date: 12/7/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
1, 2 Annual leak detection certification not completed (Required annually).
1, 2 Annual line precision and mechanical line leak detector functional test not completed.
Facility Financial responsibility must be reported yearly - After new ownership has been accepted, submit online form for financial responsibility. Financial Responsibility must be declared annually. The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility
Facility Missing copies of Annual Walkthrough Inspection Report.
1, 2 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
Facility Submit Notification Form For Ownership Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. This form is required to be submitted within 30 days of an ownership change.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/8/2024 11/8/2027
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 11/8/2024 11/8/2027
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/30/2024 9/30/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/30/2024 9/30/2025
Overfill Prev Device Overfill Drop Tube Valve 9/8/2023 9/8/2026
Piping Flexible Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/8/2023 9/8/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 10/4/2024



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/8/2024 11/8/2027
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 11/8/2024 11/8/2027
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/30/2024 9/30/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/30/2024 9/30/2025
Overfill Prev Device Overfill Drop Tube Valve 9/8/2023 9/8/2026
Piping Flexible Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/8/2023 9/8/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 10/4/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
7008359 The Cupboard Campbell Hill 11/01/2024 Letter Form