Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6047868
Status: Inactive
Facility Name: CMS Garage
Address: 1104 Eastport Plaza Drive Collinsville, IL 62234
County: Madison
Property Parcel: 000000000
Facility Type: State
Owner Type: State
Green Tag Decal:
Green Tag Issue Date:
Green Tag Expire Date:
MFD Type: N/A

Owner Details

Owner Name: State of Illinois Central Management Services
Owner Address: 313 S. 6th Street Springfield, IL 62701
Owner Status: Current Owner
Purchase Date: 1/1/1901
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 3/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041530 State of Illinois Central Management Services Current Owner 1/1/1901
U0007371 IDOT District #8 Former Owner 3/21/2011

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020252748 (Referred to Legal)    Issue Date: 10/16/2025    Expiration Date: 12/15/2025    View NOV Form

Tanks Violations
3 Submit Notification Form For Tank Status Change - The tank is no longer being used. A notification form must be submitted changing the status to out of service.

NOV Number: E0020252750 (Referred to Legal)    Issue Date: 10/16/2025    Expiration Date: 12/15/2025    View NOV Form

Tanks Violations
1, 2 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use: Dispensing
Product: Diesel Fuel CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/25/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date: 11/24/2025
Last Used Date: 10/27/2022 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/28/2021 4/28/2022
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 6/17/2024 6/17/2025
Overfill Prev Device Overfill Drop Tube Valve 4/2/2019 4/2/2022
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/2/2019 4/2/2022
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/24/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date: 11/24/2025
Last Used Date: 10/27/2022 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/28/2021 4/28/2022
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 6/17/2024 6/17/2025
Overfill Prev Device Overfill Drop Tube Valve 4/2/2019 4/2/2022
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/2/2019 4/2/2022
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 1000 Petroleum Use: Storage Only
Product: Used Oil CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/24/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date: 1/7/2026
Last Used Date: 10/16/2025 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Gravity Feed Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 6/17/2024 6/17/2025
Overfill Prev Device Less than 25 gallon fills Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Field Constructed less than 25 gallon fills Not applicable Not applicable
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms