Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6041155
Status: Inactive
Facility Name: Bhalla Holdings, LLC
Address: 402 W. Johnson Street Pocahontas, IL 62275
County: Bond
Property Parcel: 08-09-33-405-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001745
Green Tag Issue Date: 5/14/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Bhalla Holdings, LLC
Owner Address: 11 South Meadow Court South Barrington, IL 60010
Owner Status: Current Owner
Purchase Date: 10/30/2024
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041385 Bhalla Holdings, LLC Current Owner 10/30/2024
U0035716 W.T. Funderburk, Inc. Former Owner 3/1/2010
U0035550 Sunshine Energy IL, LLC Former Owner 9/4/2009
U0030705 Crescent Oil Co. Former Owner 7/18/2002

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250452 (Referred to Legal)    Issue Date: 2/24/2025    Expiration Date: 4/25/2025    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly - Financial Responsibility must be declared annually. The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
1, 2, 3 Submit Notification Form For Tank Status Change - Tanks are out of service. The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. This form is required to be submitted within 30 days of a tank status change.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/15/2003 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 7/18/2002 Red Tag Issue Date:
Last Used Date: 11/1/2024 Fee Due: $0.00
Product Date: 7/24/2002

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/9/2022 3/9/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/12/2023 9/12/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/12/2023 9/12/2024
Overfill Prev Device Overfill Drop Tube Valve 9/23/2021 9/23/2024
Piping Fiberglass Single Wall Piping Ameron Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 9/23/2021 9/23/2024
Tank Composite Single Wall ACT 100 Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 9/12/2023



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/15/2003 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 7/18/2002 Red Tag Issue Date:
Last Used Date: 11/1/2024 Fee Due: $0.00
Product Date: 7/24/2002

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/9/2022 3/9/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/12/2023 9/12/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/12/2023 9/12/2024
Overfill Prev Device Overfill Drop Tube Valve 9/23/2021 9/23/2024
Piping Fiberglass Single Wall Piping Ameron Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 9/23/2021 9/23/2024
Tank Composite Single Wall ACT 100 Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 9/12/2023



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/15/2003 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 7/18/2002 Red Tag Issue Date:
Last Used Date: 11/1/2024 Fee Due: $0.00
Product Date: 7/24/2002

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/9/2022 3/9/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/12/2023 9/12/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/12/2023 9/12/2024
Overfill Prev Device Overfill Drop Tube Valve 9/23/2021 9/23/2024
Piping Fiberglass Single Wall Piping Ameron Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 9/23/2021 9/23/2024
Tank Composite Single Wall ACT 100 Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 9/12/2023

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found