Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6038105
Status: Active
Facility Name: Kristy Food Mart, Inc.
Address: 225 McCambridge Avenue
Madison, IL 62060
County: Madison
Property Parcel: 21-2-19-25-16-404-006.001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002000
Green Tag Issue Date: 11/7/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: YG Fuel Mart, Inc.
Owner Address: 225 McCambridge Avenue
Madison, IL 62060
Owner Status: Current Owner
Purchase Date: 2/18/2022
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/4/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/7/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041041 YG Fuel Mart, Inc. Current Owner 2/18/2022
U0035651 Quick Stop & Save, Inc. Former Owner 6/1/2008
U0002560 Casey's Retail Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250531 (Pending)    Issue Date: 3/4/2025    Expiration Date: 5/3/2025    View NOV Form

Tanks Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Report not available at the time of visit.
1, 2 Document that emergency shut-off (shear valves) are in proper working order - Report not available at the time of visit.
Facility Facility Operation and Maintenance Plan not completed or available. - Report not available at the time of visit.
Facility Missing copies of 30 day Walkthrough Inspection Report. - Report not available at the time of visit.
Facility Missing copies of Annual Walkthrough Inspection Report. - Report not available at the time of visit.
Facility Missing copy of emergency instructions or emergency procedures plan - Report not available at the time of visit.
1 Water in containment without required interstitial sensors - install cathodic protection on all exposed steel. - Add cathodic protection or repair sump to prevent water intrusion.

NOV Number: E0020250532 (Pending)    Issue Date: 3/4/2025    Expiration Date: 5/3/2025    View NOV Form

Tanks Violation
Facility Fire Extinguishers - Past due for annual testing

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/2/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 3/16/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/17/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/24/2024 10/24/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/24/2024 10/24/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2023 9/18/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2023 9/18/2026
Tank Fiberglass Single Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 2/4/2020



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/2/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 3/16/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/17/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/24/2024 10/24/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/24/2024 10/24/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2023 9/18/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2023 9/18/2026
Tank Fiberglass Single Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 11/30/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms