Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6033625
Status: Active
Facility Name: Circle K #1352
Address: 12587 Illinois Route 143 Highland, IL 62249
County: Madison
Property Parcel: 02-1-18-32-02-201-007
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01688
Green Tag Issue Date: 3/18/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100 Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 2/14/2013
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 1/26/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/18/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 2/14/2013
U0004080 Dickerson Petroleum Former Owner 12/14/1994

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20220974 Eligible 12/19/2022 12/19/2022 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/27/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 12/14/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/14/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/13/2025 1/13/2026
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD 9/5/2024 9/5/2025
Overfill Prev Device Overfill Drop Tube Valve 9/5/2024 9/5/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 9/5/2024 9/5/2027
Tank Composite Single Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/5/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/27/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 12/14/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/14/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/13/2025 1/13/2026
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD 9/5/2024 9/5/2025
Overfill Prev Device Overfill Drop Tube Valve 9/5/2024 9/5/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/5/2024 9/5/2027
Tank Composite Single Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/5/2024



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/27/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 12/14/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/14/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/13/2025 1/13/2026
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD 9/5/2024 9/5/2025
Overfill Prev Device Overfill Drop Tube Valve 9/5/2024 9/5/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 12/8/2022 12/8/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 5/27/2025 5/27/2028
Tank Composite Single Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/5/2024
Tank Composite Single Wall ACT 100 Precision Test (Tank) Pass 12/12/2022



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/10/1998 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 12/14/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/14/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/5/2024 9/5/2025
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD 9/5/2024 9/5/2025
Overfill Prev Device Overfill Drop Tube Valve 1/13/2025 1/13/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/13/2025 1/13/2028
Tank Composite Single Wall ACT 100 N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/5/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found