Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6029485
Status: Active
Facility Name: Victory Lane
Address: 119 W. Cumberland Rd. Brownstown, IL 62418
County: Fayette
Property Parcel: 11-15-02-159-004
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002004
Green Tag Issue Date: 9/13/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Sensation, Inc.
Owner Address: 119 W. Cumberland Rd. Brownstown, IL 62418
Owner Status: Current Owner
Purchase Date: 6/1/2012
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 7/19/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036555 Sensation, Inc. Current Owner 6/1/2012
U0035882 Boparai, Gurbir Former Owner 1/1/2010
U0018840 McConkey , Paul & Doris Former Owner 4/6/1992

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261693 (Pending)    Issue Date: 7/1/2026    Expiration Date: 8/30/2026    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
1, 2 Annual leak detection certification not completed (Required annually). - Testing expired 9/12/2025
Facility Financial responsibility must be reported yearly - Financial Responsibility must be declared annually. The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
Facility Missing copies of Annual Walkthrough Inspection Report.
1, 2 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Testing expired 10/19/2025
1, 2 Tank sacrificial anode system not tested (Required every 3 years). - Testing expired 10/19/2025
1, 2 Triennial spill prevention equipment testing not completed. - Testing expired 10/19/2025

NOV Number: E0020261694 (Pending)    Issue Date: 7/1/2026    Expiration Date: 8/30/2026    View NOV Form

Tanks Violations
Facility Fire Extinguishers - Past due for annual testing - Last tested July 2024

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/16/1992 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 4/7/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/1992

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 10/19/2022 10/19/2025
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 9/12/2024 9/12/2025
Overfill Prev Device Overfill Drop Tube Valve 10/19/2022 10/19/2025
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 10/19/2022 10/19/2025
Tank STIP3 Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank STIP3 Single Wall Precision Test (Tank) Pass 5/14/2019



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/16/1992 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 4/7/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/1992

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 10/19/2022 10/19/2025
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 9/12/2024 9/12/2025
Overfill Prev Device Overfill Drop Tube Valve 10/19/2022 10/19/2025
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 10/19/2022 10/19/2025
Tank STIP3 Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank STIP3 Single Wall Precision Test (Tank) Pass 9/12/2024

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found