Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6026812
Status: Closed
Facility Name: One Stop Shop
Address: 2619 N. Center Street Maryville, IL 62062
County: Madison
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01738
Green Tag Issue Date: 8/14/2025
Green Tag Expire Date: 5/13/2026
MFD Type: Self Service

Owner Details

Owner Name: Satyadev, Inc.
Owner Address: P.O. Box 17 Maryville, IL 62062
Owner Status: Current Owner
Purchase Date: 7/31/2013
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/29/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036996 Satyadev, Inc. Current Owner 7/31/2013
U0016844 Kicha Enterprises, Inc. Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00497-2026REM Removal Approved / Issued 5/1/2026 5/1/2026 11/3/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2026-0303 5/12/2026 Removal Log 00497-2026REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/12/2026
OSFM First Notify Date: 1/29/1991 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/25/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 7/22/2025 7/22/2028
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 7/22/2025 7/22/2028
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/11/2025 7/11/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 7/11/2025 7/11/2026
Overfill Prev Device Overfill Drop Tube Valve 7/11/2025 7/11/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/11/2025 7/11/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/11/2025
Tank STIP3 Single Wall Precision Test (Tank) Pass 8/26/2019



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/12/2026
OSFM First Notify Date: 1/29/1991 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 8/25/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/25/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 7/22/2025 7/22/2028
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 7/22/2025 7/22/2028
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/11/2025 7/11/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 7/11/2025 7/11/2026
Overfill Prev Device Overfill Drop Tube Valve 7/11/2025 7/11/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 7/11/2025 7/11/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/11/2025
Tank STIP3 Single Wall Precision Test (Tank) Pass 8/26/2019



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/12/2026
OSFM First Notify Date: 1/29/1991 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/25/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 7/22/2025 7/22/2028
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 7/22/2025 7/22/2028
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/11/2025 7/11/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 7/11/2025 7/11/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 7/11/2025 7/11/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/11/2025 7/11/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/11/2025
Tank STIP3 Single Wall Precision Test (Tank) Pass 8/26/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms