Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6021607
Status: Active
Facility Name: KKG2, Inc. d/b/a Salem Citgo
Address: 514 South Broadway Salem, IL 62881
County: Marion
Property Parcel: 11-00-009-205
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000005
Green Tag Issue Date: 12/15/2022
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: ARG KK10PCK001, LLC
Owner Address: 38 Washington Square Newport, RI 02840
Owner Status: Current Owner
Purchase Date: 12/11/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/3/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/15/2022 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040111 ARG KK10PCK001, LLC Current Owner 12/11/2020
U0008547 Knapp Oil Company, Inc. Former Owner 11/1/1987

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251157 (Referred to Legal)    Issue Date: 5/2/2025    Expiration Date: 7/1/2025    View NOV Form

Tanks Violations
5 Submit Notification Form For Tank Status Change - k1 tank must be placed out of service if no longer going to be used.
5 Tank monitor does not appear to function properly and requires maintenance. - K1 Probe is out..

NOV Number: E0020251158 (Referred to Legal)    Issue Date: 5/2/2025    Expiration Date: 7/1/2025    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - System is inoperable.

NOV Number: E0020251728 (Pending)    Issue Date: 7/9/2025    Expiration Date: 9/7/2025    View NOV Form

Tanks Violations
Facility Due to a red tagged tank(s) at this facility, after 60 days from the issuance date of this NOV, in the absence of full compliance, all tanks shall be red tagged - Tank #5 (K1) must be placed out of service if no longer going to be used.
Facility Due to outstanding Motor Fuel Dispensing violation(s) at this facility, after 60 days from the issuance date of this Notice of Violation, and in the absence of full compliance, all tanks shall be red tagged. - Communication system is inoperable.
5 Submit Notification Form For Tank Status Change - K1 tank must be placed out of service if no longer going to be used.
5 Tank monitor does not appear to function properly and requires maintenance. - K1 probe is out.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
18-01180 9/6/2018 Removal Log 01180-2018REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20180763 Eligible 10/15/2018 10/18/2018 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/6/2018
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: 9/1/2018 Fee Due: $0.00
Product Date: 1/1/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/8/2015 7/8/2018
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 1/14/2014 1/14/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/28/2017 11/28/2018
Leak Detect - Tank Ground Water Monitoring Wells
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/6/2018
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: 9/1/2018 Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/8/2015 7/8/2018
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 1/14/2014 1/14/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/28/2017 11/28/2018
Leak Detect - Tank Ground Water Monitoring Wells
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/2/1997 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 8/21/2024 8/21/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2024 8/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 8/21/2024 8/21/2025
Overfill Prev Device Overfill Drop Tube Valve 8/21/2024 8/21/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/21/2024 8/21/2027
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/8/2019
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 8/21/2024



Tank Number 4

Capacity: 8000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/2/1997 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 8/21/2024 8/21/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2024 8/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 8/21/2024 8/21/2025
Overfill Prev Device Overfill Drop Tube Valve 8/21/2024 8/21/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/21/2024 8/21/2027
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/30/2025



Tank Number 5

Capacity: 1000 Petroleum Use: None
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/2/1997 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/1/1987 Red Tag Issue Date: 7/9/2025
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 8/21/2024 8/21/2027
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 8/31/2023 8/21/2024
Overfill Prev Device Overfill Drop Tube Valve 8/21/2024 8/21/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/21/2024 8/21/2027
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/8/2019
Tank STIP3 Single Wall Precision Test (Tank) Pass 6/30/2025



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/11/2018 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 9/18/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/19/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Jacketed Steel Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2024 8/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 8/21/2024 8/21/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/21/2024 8/21/2025
Overfill Prev Device Overfill Drop Tube Valve 8/21/2024 8/21/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/21/2024 8/21/2027
Tank Jacketed Steel Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/L Precision Test (Piping) Pass 10/8/2019
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 8/21/2024



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/11/2018 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 9/18/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/19/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/21/2024 8/21/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Jacketed Steel Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2024 8/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 8/21/2024 8/21/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/21/2024 8/21/2025
Overfill Prev Device Overfill Drop Tube Valve 8/21/2024 8/21/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/21/2024 8/21/2027
Tank Jacketed Steel Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/L Precision Test (Piping) Pass 10/8/2019
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 8/21/2024



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID K1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found