Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6019212
Status: Active
Facility Name: CC Food Mart
Address: 1011 W. Hwy 50 O Fallon, IL 62269
County: St. Clair
Property Parcel: 03-25.0-400-025
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA001693
Green Tag Issue Date: 3/28/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Clinton County Oil Company, Inc.
Owner Address: P.O. Box 155 Breese, IL 62230
Owner Status: Current Owner
Purchase Date: 2/2/1985
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 12/11/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0003121 Clinton County Oil Company, Inc. Current Owner 2/2/1985

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
0712-96 9/6/1996 Removal Log
96-1643 9/6/1996 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-3092 Eligible 6/24/1994 7/15/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/6/1996
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 9/4/1996 Fee Due: $0.00
Product Date: 1/1/1975

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/6/1996
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 9/4/1996 Fee Due: $0.00
Product Date: 1/1/1975

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/6/1996
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 9/4/1996 Fee Due: $0.00
Product Date: 1/1/1975

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 300 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 10/1/1990
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/22/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 6/26/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/15/2026 4/15/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/15/2026 4/15/2027
Overfill Prev Device Ball Float Vent Valve 1/16/2025 1/16/2028
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor 1/16/2025 1/16/2028
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/22/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 6/26/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/15/2026 4/15/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/15/2026 4/15/2027
Overfill Prev Device Ball Float Vent Valve 1/16/2025 1/16/2028
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor 1/16/2025 1/16/2028
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2008 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 6/26/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/15/2026 4/15/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/15/2026 4/15/2027
Overfill Prev Device Overfill Drop Tube Valve 1/16/2025 1/16/2028
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor 1/16/2025 1/16/2028
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found