Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6018498
Status: Active
Facility Name: Pilot Travel Center #249
Address: 820 Edwardsville Road Troy, IL 62294
County: Madison
Property Parcel: 09-1-22-08-00-000-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01759
Green Tag Issue Date: 9/29/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Pilot Travel Centers, LLC
Owner Address: 5508 Lonas Rd. Knoxville, TN 37909
Owner Status: Current Owner
Purchase Date: 10/24/2014
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/18/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0011913 Pilot Travel Centers, LLC Current Owner 10/24/2014
U0026141 Hgc Ltd Partnership Former Owner 7/17/1997
U0023819 Pilot Travel Centers, L.L.C. Former Owner 6/6/1997
U0020768 Allen Corporation Former Owner 10/20/1992
U0008434 Key Pantries Inc Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
02-0259 2/25/2002 Removal Log 00276-2002REM
02-0259 2/28/2002 Removal Log 00276-2002REM
92-3481 12/7/1992 Removal Log 6786-92

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-1273 Eligible 8/21/1998 10/6/1998 $15,000
02-0259 Eligible 8/6/2002 9/12/2002 $15,000
15-0875 Eligible 1/22/2016 3/2/2016 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/25/2002
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 2/25/2002 Fee Due: $0.00
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/25/2002
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 2/25/2002 Fee Due: $0.00
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/25/2002
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 2/25/2002 Fee Due: $0.00
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/25/2002
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 2/25/2002 Fee Due: $0.00
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/25/2002
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 2/25/2002 Fee Due: $0.00
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/25/2002
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 2/25/2002 Fee Due: $0.00
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 2000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/7/1992
OSFM First Notify Date: 9/20/1990 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 5/3/1968 Red Tag Issue Date:
Last Used Date: 11/28/1990 Fee Due: $0.00
Product Date: 5/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 2000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 12/7/1992
OSFM First Notify Date: 9/20/1990 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 5/3/1968 Red Tag Issue Date:
Last Used Date: 11/28/1990 Fee Due: $0.00
Product Date: 5/3/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/4/1997 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 9/1/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/15/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/21/2025 9/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/22/2025 9/22/2026
Leak Detect - Tank Vacuum Gauge 9/22/2025 9/22/2026
Overfill Prev Device Overfill Drop Tube Valve 10/12/2023 10/12/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/14/2025 7/14/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Piping Single Wall Transition Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Spill Contain Device Double Wall Spill Bucket 3/8/2025 3/8/2028
Tank Composite Double Wall Permatank N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 7/17/2025
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 12/15/2020
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 1/6/2021



Tank Number 10

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/29/2002 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 2/26/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/26/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/21/2025 9/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/22/2025 9/22/2026
Leak Detect - Tank Vacuum Veeder Root Secondary Containment Vacuum Sensing System (Tank) 9/22/2025 9/22/2026
Overfill Prev Device Overfill Drop Tube Valve 10/12/2023 10/12/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Piping Single Wall Transition Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Spill Contain Device Double Wall Spill Bucket 3/8/2025 3/8/2028
Tank Composite Double Wall Permatank N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/9/2024
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 12/15/2020
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 1/6/2021



Tank Number 11

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/29/2002 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 2/26/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/26/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/21/2025 9/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/22/2025 9/22/2026
Leak Detect - Tank Vacuum Veeder Root Secondary Containment Vacuum Sensing System (Tank) 9/29/2025 9/29/2026
Overfill Prev Device Overfill Drop Tube Valve 10/12/2023 10/12/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Piping Single Wall Transition Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Spill Contain Device Single Wall Spill Bucket 3/8/2025 3/8/2028
Tank Composite Double Wall Permatank N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/9/2024
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 12/15/2020
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 1/6/2021



Tank Number 12

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/29/2002 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 2/26/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/26/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/21/2025 9/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/29/2025 9/29/2026
Leak Detect - Tank Vacuum Veeder Root Secondary Containment Vacuum Sensing System (Tank) 9/29/2025 9/29/2026
Overfill Prev Device Overfill Drop Tube Valve 2/7/2025 2/7/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Piping Single Wall Transition Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Spill Contain Device Double Wall Spill Bucket 3/8/2025 3/8/2028
Tank Composite Double Wall Permatank N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/9/2024
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 12/15/2020
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 1/6/2021



Tank Number 13

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/20/2002
OSFM First Notify Date: 7/5/2002 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 2/26/2002 Red Tag Issue Date:
Last Used Date: 3/1/2002 Fee Due: $0.00
Product Date: 2/26/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 14

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/29/2002 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 3/21/2002 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 3/21/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/21/2025 9/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/29/2025 9/29/2026
Leak Detect - Tank Vacuum Gauge 9/22/2025 9/22/2026
Overfill Prev Device Overfill Drop Tube Valve 10/12/2023 10/12/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/22/2025 9/22/2026
Spill Contain Device Double Wall Spill Bucket 3/8/2025 3/8/2028
Tank Composite Double Wall Permatank N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/9/2024
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 12/15/2020
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 1/6/2021



Tank Number 15

Capacity: 20000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/16/2007 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 1/23/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/23/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/29/2025 9/29/2026
Leak Detect - Tank Vacuum Gauge 9/22/2025 9/22/2026
Overfill Prev Device Overfill Drop Tube Valve 11/10/2023 11/10/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Blending Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 9/29/2025 9/29/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/8/2025 3/8/2028
Leak Detect - Piping Sump Sensor 10/10/2024 10/10/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/8/2025 3/8/2028
Tank Steel Double Wall Highland Tank Titan Jacketed N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/27/2022
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 1/6/2021
Tank Steel Double Wall Highland Tank Titan Jacketed Precision Test (Tank) Pass 12/15/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 17M/18S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 17S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 18M/19S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 19M/20S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 20M/21S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 21M/22S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 22M/23S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 23M/24S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 24M/25S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 25M/26S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 26M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/8/2025 3/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID Removed 3/4

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed 5/6

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed 7/8

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed 9/10

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D16

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D17

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D18

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D19

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D20

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D21

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D22

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D23

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D24

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D25

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date



Name\ID Removed D26

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date

MFD Motorfuel Dispensing Forms

No Forms Found