Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0037728 |
GPM Midwest, LLC |
Current Owner |
3/20/2015 |
| U0031916 |
Parsons Oil Co., LLC |
Former Owner |
2/4/2004 |
| U0011885 |
Piasa Motor Fuels, Inc. |
Former Owner |
7/10/1976 |
| U0033990 |
Road Ranger, LLC |
Former Owner |
|
Permits (Unexpired)
Click for permit history
| Permit Number |
Type |
Status |
OSFM Receive Date |
Issue Date |
Expiration Date |
Documents |
| 00195-2026UPG |
Upgrade |
Approved / Issued |
2/18/2026 |
2/18/2026 |
8/18/2026 |
Documents |
| 00322-2026ENT |
Tank Entry |
Approved / Issued |
3/25/2026 |
3/25/2026 |
9/25/2026 |
Documents |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 07-0902 |
10/24/2007 |
Removal Log |
01294-2007REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 07-0902 |
Eligible |
12/18/2007
|
1/10/2008
|
$15,000
|
|
| 20230640 |
Eligible |
7/18/2025
|
7/18/2025
|
$5,000
|
Letter
|
Tank Number 5
| Capacity: |
2000 |
|
Petroleum Use: |
|
| Product: |
Kerosene |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/24/2007 |
|
OSFM
First Notify Date: |
3/24/1992 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
6/15/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/23/2007 |
|
Fee Due: |
$0.00 |
| Product Date: |
6/15/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
No passing test found |
No passing test found |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 6
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/24/2007 |
|
OSFM
First Notify Date: |
10/24/1994 |
|
Abandoned Material: |
|
| Current Age: |
13 |
|
Abandoned Date: |
|
| Install Date: |
7/10/1994 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/23/2007 |
|
Fee Due: |
$0.00 |
| Product Date: |
7/10/1994 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Composite Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 7
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/24/2007 |
|
OSFM
First Notify Date: |
4/18/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
7/10/1976 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/23/2007 |
|
Fee Due: |
$0.00 |
| Product Date: |
7/10/1976 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
No passing test found |
No passing test found |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 8
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/24/2007 |
|
OSFM
First Notify Date: |
4/18/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
7/10/1976 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/23/2007 |
|
Fee Due: |
$0.00 |
| Product Date: |
7/10/1976 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
No passing test found |
No passing test found |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 9
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/24/2007 |
|
OSFM
First Notify Date: |
4/18/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
7/10/1976 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/23/2007 |
|
Fee Due: |
$0.00 |
| Product Date: |
7/10/1976 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
No passing test found |
No passing test found |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 10
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/24/2007 |
|
OSFM
First Notify Date: |
4/18/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
7/10/1976 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
9/11/2007 |
|
Fee Due: |
$0.00 |
| Product Date: |
7/10/1976 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
No passing test found |
No passing test found |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
No passing test found |
No passing test found |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 11
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/18/2007 |
|
Abandoned Material: |
|
| Current Age: |
18 |
|
Abandoned Date: |
|
| Install Date: |
10/30/2007 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/31/2007 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/19/2026 |
1/19/2029 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/19/2026 |
1/19/2029 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
1/22/2026 |
1/22/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
1/19/2026 |
1/19/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
1/22/2025 |
1/22/2028 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/25/2024 |
3/25/2027 |
Leak Detect - Piping
|
Sump Sensor |
3/25/2024 |
3/25/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
1/22/2025 |
1/22/2028 |
|
Tank
|
Fiberglass Single Wall Containment Solutions |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron
|
Precision Test (Piping)
|
Pass
|
1/22/2026
|
|
Tank
|
Fiberglass Single Wall Containment Solutions
|
Precision Test (Tank)
|
Pass
|
1/22/2026
|
Tank Number 12
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/18/2007 |
|
Abandoned Material: |
|
| Current Age: |
18 |
|
Abandoned Date: |
|
| Install Date: |
10/30/2007 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/31/2007 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/19/2026 |
1/19/2029 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/19/2026 |
1/19/2029 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
1/22/2026 |
1/22/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
1/19/2026 |
1/19/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
1/22/2025 |
1/22/2028 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/25/2024 |
3/25/2027 |
Leak Detect - Piping
|
Sump Sensor |
3/25/2024 |
3/25/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
1/22/2025 |
1/22/2028 |
|
Tank
|
Fiberglass Single Wall Containment Solutions |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron
|
Precision Test (Piping)
|
Pass
|
1/22/2026
|
|
Tank
|
Fiberglass Single Wall Containment Solutions
|
Precision Test (Tank)
|
Pass
|
1/22/2026
|
Tank Number 13
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/18/2007 |
|
Abandoned Material: |
|
| Current Age: |
18 |
|
Abandoned Date: |
|
| Install Date: |
10/30/2007 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/31/2007 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/19/2026 |
1/19/2029 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/19/2026 |
1/19/2029 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
1/22/2026 |
1/22/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
1/19/2026 |
1/19/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
1/22/2025 |
1/22/2028 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/25/2024 |
3/25/2027 |
Leak Detect - Piping
|
Sump Sensor |
3/25/2024 |
3/25/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
1/22/2025 |
1/22/2028 |
|
Tank
|
Fiberglass Single Wall Containment Solutions |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron
|
Precision Test (Piping)
|
Pass
|
1/22/2026
|
|
Tank
|
Fiberglass Single Wall Containment Solutions
|
Precision Test (Tank)
|
Pass
|
4/29/2026
|
Tank Number 14
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/18/2007 |
|
Abandoned Material: |
|
| Current Age: |
18 |
|
Abandoned Date: |
|
| Install Date: |
10/30/2007 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/31/2007 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
1/22/2026 |
1/22/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
1/22/2026 |
1/22/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
1/19/2026 |
1/19/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
1/22/2025 |
1/22/2028 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/25/2024 |
3/25/2027 |
Leak Detect - Piping
|
Sump Sensor |
3/25/2024 |
3/25/2027 |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/25/2024 |
3/25/2027 |
Leak Detect - Piping
|
Sump Sensor |
3/25/2024 |
3/25/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
3/17/2025 |
3/17/2028 |
|
Tank
|
Fiberglass Single Wall Containment Solutions |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron
|
Precision Test (Piping)
|
Pass
|
1/22/2026
|
|
Tank
|
Fiberglass Single Wall Containment Solutions
|
Precision Test (Tank)
|
Pass
|
1/22/2026
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
| Facility Number |
Name |
City |
Received Date |
Letter |
|
6016541
|
Fas Mart #5154
|
Hartford
|
05/06/2025
|
Letter
Form
|