Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0033990 |
Road Ranger, LLC |
Current Owner |
10/4/2012 |
| U0028363 |
JEHC Development Inc. |
Former Owner |
8/5/1999 |
| U0034191 |
JEHL Development, Inc. |
Former Owner |
1/1/1999 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 12-1078 |
Eligible |
12/6/2012
|
12/28/2012
|
$5,000
|
|
Tank Number 1
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
11/22/1999 |
|
Abandoned Material: |
|
| Current Age: |
26 |
|
Abandoned Date: |
|
| Install Date: |
8/5/1999 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/5/1999 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
2/23/2026 |
2/23/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 with CSLD |
2/23/2026 |
2/23/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
2/4/2025 |
2/4/2028 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech |
Not applicable |
Not applicable |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/14/2025 |
3/14/2028 |
Leak Detect - Piping
|
Sump Sensor |
3/14/2025 |
3/14/2028 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/22/2024 |
10/22/2027 |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech
|
Precision Test (Piping)
|
Pass
|
2/23/2026
|
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
11/22/1999 |
|
Abandoned Material: |
|
| Current Age: |
26 |
|
Abandoned Date: |
|
| Install Date: |
8/5/1999 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/5/1999 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
2/23/2026 |
2/23/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
2/23/2026 |
2/23/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/9/2025 |
5/9/2028 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech |
Not applicable |
Not applicable |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/22/2024 |
10/22/2027 |
Leak Detect - Piping
|
Sump Sensor |
10/22/2024 |
10/22/2027 |
|
Piping
|
Single Wall Transition Sump |
10/22/2024 |
10/22/2027 |
Leak Detect - Piping
|
Sump Sensor |
10/22/2024 |
10/22/2027 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
5/9/2025 |
5/9/2028 |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech
|
Precision Test (Piping)
|
Pass
|
2/23/2026
|
|
Tank
|
Composite Single Wall ACT 100
|
Precision Test (Tank)
|
Pass
|
2/23/2026
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
|
Precision Test (Tank)
|
Pass
|
12/17/2018
|
Tank Number 3
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
11/22/1999 |
|
Abandoned Material: |
|
| Current Age: |
26 |
|
Abandoned Date: |
|
| Install Date: |
8/5/1999 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/5/1999 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/22/2024 |
10/22/2027 |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
2/23/2026 |
2/23/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 with CSLD |
2/23/2026 |
2/23/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/9/2025 |
5/9/2028 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech |
Not applicable |
Not applicable |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/22/2024 |
10/22/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/22/2024 |
10/22/2027 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
5/9/2025 |
5/9/2028 |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech
|
Precision Test (Piping)
|
Pass
|
2/23/2026
|
|
Tank
|
Composite Single Wall ACT 100
|
Precision Test (Tank)
|
Pass
|
3/13/2025
|
Tank Number 4
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/18/2012 |
|
Abandoned Material: |
|
| Current Age: |
13 |
|
Abandoned Date: |
|
| Install Date: |
10/18/2012 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/20/2012 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
2/23/2026 |
2/23/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
2/23/2026 |
2/23/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
2/23/2026 |
2/23/2027 |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VML |
10/22/2024 |
10/22/2027 |
|
Overfill Prev Device
|
Overfill Alarm |
6/15/2026 |
6/15/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/22/2024 |
10/22/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/22/2024 |
10/22/2027 |
|
Piping
|
Single Wall Transition Sump |
10/22/2024 |
10/22/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/22/2024 |
10/22/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/22/2024 |
10/22/2027 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
2/23/2026
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
2/23/2026
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
|
Precision Test (Tank)
|
Pass
|
12/17/2019
|
Tank Number 5
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
B-99 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/18/2012 |
|
Abandoned Material: |
|
| Current Age: |
13 |
|
Abandoned Date: |
|
| Install Date: |
10/18/2012 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/20/2012 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
2/23/2026 |
2/23/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
3/23/2026 |
3/23/2027 |
|
Overfill Prev Device
|
Overfill Alarm |
6/15/2026 |
6/15/2029 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/14/2025 |
5/14/2028 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/22/2024 |
10/22/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/22/2024 |
10/22/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/22/2024 |
10/22/2027 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
2/23/2026
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
2/23/2026
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
|
Precision Test (Tank)
|
Pass
|
12/8/2020
|
Tank Number 6
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Diesel Exhaust Fluid (Non-Regulated) |
|
CERCLA Substance: |
|
| Status: |
Unknown |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/18/2012 |
|
Abandoned Material: |
|
| Current Age: |
13 |
|
Abandoned Date: |
|
| Install Date: |
10/18/2012 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
10/20/2012 |
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found