Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5036934
Status: Active
Facility Name: Havana Fuels, Inc.
Address: 520 Laurel Ave. Havana, IL 62644
County: Mason
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000652
Green Tag Issue Date: 2/2/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Havana Fuels, Inc.
Owner Address: 520 Laurel Havana, IL 62644
Owner Status: Current Owner
Purchase Date: 12/28/2010
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 10/1/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/2/2024 12/31/2025
Unattended Self Service 7/20/2015 12/31/2017

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036029 Havana Fuels, Inc. Current Owner 12/28/2010
U0027069 Mason County Service Former Owner 9/1/2002
U0031126 Sunrise Ag. Service Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251080 (Pending)    Issue Date: 4/21/2025    Expiration Date: 6/20/2025    View NOV Form

Tanks Violations
1 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Tank 1 STP Sump cover lid needs to be repaired or replaced.
1, 2, 3, 4 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Overfill Alarm test has expired.
1, 3, 4 Triennial spill prevention equipment testing not completed.
1, 2, 3, 4 Triennial testing for qualifying piping containment sump not completed (Required every 3 years).

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/11/1999 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/1/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/20/2025 2/20/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/20/2025 2/20/2026
Overfill Prev Device Overfill Alarm 6/24/2025 6/24/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026
Spill Contain Device Single Wall Spill Bucket 6/24/2025 6/24/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 2/20/2025



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/11/1999 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/1/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/20/2025 2/20/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/20/2025 2/20/2026
Overfill Prev Device Overfill Alarm 6/24/2025 6/24/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026
Spill Contain Device Double Wall Spill Bucket 6/24/2025 6/24/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 2/20/2025



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/11/1999 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/1/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/20/2025 2/20/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/20/2025 2/20/2026
Overfill Prev Device Overfill Alarm 6/24/2025 6/24/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026
Spill Contain Device Single Wall Spill Bucket 3/7/2022 3/7/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 2/20/2025



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/11/1999 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/1/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/20/2025 2/20/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/20/2025 2/20/2026
Overfill Prev Device Overfill Alarm 6/24/2025 6/24/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026
Spill Contain Device Single Wall Spill Bucket 6/24/2025 6/24/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 2/20/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026



Name\ID 10 satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026



Name\ID 7/8 master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026



Name\ID 9 satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/24/2025 6/24/2028
Leak Detect - Piping Sump Sensor 2/20/2025 2/20/2026

MFD Motorfuel Dispensing Forms

No Forms Found