Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5035693
Status: Active
Facility Name: Pioneer Express
Address: 204 S. Clover Perry, IL 62362
County: Pike
Property Parcel: 33-034-02
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01506
Green Tag Issue Date: 7/21/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Arisha Enterprises, Inc.
Owner Address: 701 W. Quincy Street Pleasant Hill, IL 62366
Owner Status: Current Owner
Purchase Date: 7/22/2025
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 9/9/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041554 Arisha Enterprises, Inc. Current Owner 7/22/2025
U0036688 Pioneer Express, LLC Former Owner 12/20/2011
U0033685 Perry Quickmart, Inc. Former Owner 9/1/2006
U0030686 Hoaglin Convenience Stores, Inc. Former Owner 10/11/2002
U0025888 Mcgrew Chuck Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261119 (Pending)    Issue Date: 4/27/2026    Expiration Date: 6/26/2026    View NOV Form

Tanks Violations
2 Line leak detection equipment in alarm or failed test, must repair or replace. - Mechanical Pressurized Line Leak Detection Failed test 11/3/2025.
Facility Missing copies of 30 day Walkthrough Inspection Report.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/3/2000 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 8/27/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/9/2026 1/9/2029
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/9/2026 1/9/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 11/3/2025 11/3/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 1/9/2026 1/9/2029
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/1/2024 10/1/2027
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 11/3/2025



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/3/2000 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 8/27/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/9/2026 1/9/2029
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/1/2024 10/1/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 11/3/2025 11/3/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 1/9/2026 1/9/2029
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/1/2024 10/1/2027
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 11/3/2025



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/3/2000 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 8/27/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/9/2026 1/9/2029
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/9/2026 1/9/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 11/3/2025 11/3/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 1/9/2026 1/9/2029
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/1/2024 10/1/2027
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 11/3/2025



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/3/2000 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 8/27/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/9/2026 1/9/2029
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/9/2026 1/9/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 11/3/2025 11/3/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 1/9/2026 1/9/2029
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/1/2024 10/1/2027
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 11/3/2025

Dispenser Information



Name\ID 1&2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3&4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5&6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found