Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5029235
Status: Active
Facility Name: Virden Fast Stop
Address: 1304 N. Springfield St., Rt. 4 Virden, IL 62690
County: Macoupin
Property Parcel:
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: AA01538
Green Tag Issue Date: 9/18/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service; Unattended Self Service

Owner Details

Owner Name: J. D. Streett & Company, Inc.
Owner Address: 144 Weldon Parkway Maryland Heights, MO 63043
Owner Status: Current Owner
Purchase Date: 1/27/2026
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0007830 J. D. Streett & Company, Inc. Current Owner 1/27/2026
U0027595 M & M Service Company Former Owner 10/1/1991
U0009545 Macoupin Ser Co Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00303-2026UPG Upgrade Approved / Issued 3/18/2026 3/19/2026 9/21/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
02-1045 Eligible 2/7/2003 2/26/2003 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/24/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/11/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/12/2026 3/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2026 3/12/2027
Overfill Prev Device Overfill Drop Tube Valve 3/28/2023 3/28/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 4/8/2026 4/8/2029
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/12/2026



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/24/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/11/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/12/2026 3/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2026 3/12/2027
Overfill Prev Device Overfill Drop Tube Valve 3/28/2023 3/28/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 4/8/2026 4/8/2029
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/12/2026



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/24/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/11/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/12/2026 3/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2026 3/12/2027
Overfill Prev Device Overfill Drop Tube Valve 3/28/2023 3/28/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 4/8/2026 4/8/2029
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/12/2026



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/24/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/11/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/14/2024 9/14/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/12/2026 3/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2026 3/12/2027
Overfill Prev Device Overfill Drop Tube Valve 3/28/2023 3/28/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 4/8/2026 4/8/2029
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/12/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 10/11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9 satelite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms