Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5026947
Status: Closed
Facility Name: Village of Ashland
Address: Se Corner Charles & Washington Ashland, IL 62612
County: Cass
Property Parcel:
Facility Type: City / Town
Owner Type: Municipal
Green Tag Decal: Y003631
Green Tag Issue Date: 11/22/2023
Green Tag Expire Date: 12/31/2025
MFD Type: N/A

Owner Details

Owner Name: Village of Ashland
Owner Address: 101 N Yates Po Box 170 Ashland, IL 62612
Owner Status: Current Owner
Purchase Date: 5/15/1984
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/29/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0017131 Village of Ashland Current Owner 5/15/1984

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/17/2025
OSFM First Notify Date: 4/26/1991 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 5/15/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/15/1984

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank 110 - 600 gallons Manual Tank Gauging Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 10/2/2023 10/2/2026
Piping Flexible Double Wall Environ Geo Flex Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 10/2/2023 10/2/2026
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms