Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5018694
Status: Active
Facility Name: Ameren Illinois Springfield Operating Center
Address: 825 North MacArthur Blvd. Springfield, IL 62702
County: Sangamon
Property Parcel: 14-28.0-153-003
Facility Type: Utility
Owner Type: Private
Green Tag Decal: Z000572
Green Tag Issue Date: 8/29/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Fleet

Owner Details

Owner Name: Ameren Illinois
Owner Address: 300 Liberty Street Peoria, IL 61602
Owner Status: Current Owner
Purchase Date: 10/1/2010
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038114 Ameren Illinois Current Owner 10/1/2010
U0002654 Central Illinois Light Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
88-0837 2/19/1991 Removal Log

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 25

Capacity: 1500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 3/27/1986 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 26

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 3/27/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 27

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 3/27/1988 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 28

Capacity: 200 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 3/27/1986 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 29

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/10/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 1/1/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1991

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/8/2026 1/8/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/8/2026 1/8/2027
Overfill Prev Device Overfill Drop Tube Valve 1/17/2025 1/17/2028
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 1/17/2025 1/17/2028
Leak Detect - Piping Sump Sensor 1/17/2025 1/17/2028
Spill Contain Device Single Wall Spill Bucket 1/17/2025 1/17/2028
Tank Fiberglass Double Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 1/8/2026



Tank Number 30

Capacity: 4000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/10/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 4/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1991

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/8/2026 1/8/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/8/2026 1/8/2027
Overfill Prev Device Overfill Drop Tube Valve 1/17/2025 1/17/2028
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 1/17/2025 1/17/2028
Leak Detect - Piping Sump Sensor 1/17/2025 1/17/2028
Spill Contain Device Single Wall Spill Bucket 1/17/2025 1/17/2028
Tank Fiberglass Double Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 1/8/2026



Tank Number 31

Capacity: 500 Petroleum Use: None
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/10/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 4/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1991

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Gravity Feed Not applicable Not applicable
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/10/2026 7/10/2027
Leak Detect - Tank 110 - 600 gallons Manual Tank Gauging Not applicable Not applicable
Overfill Prev Device Less than 25 gallon fills Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 1/17/2025 1/17/2028
Tank Fiberglass Double Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found