Facility Details
Facility Number:
5013581
Status:
Closed
Facility Name:
Curry Ready Mix & Builders Supply
Address:
3600 N. Dirksen Pkwy
Springfield, IL 62703
County:
Sangamon
Property Parcel:
Facility Type:
Commercial / Retail
Owner Type:
Private
Green Tag Decal:
L002300
Green Tag Issue Date:
8/6/2010
Green Tag Expiration Date:
12/31/2012
Owner Details
Owner Name:
Curry Ready Mix & Builders Supply
Owner Address:
3600 N. Dirksen Pkwy
Springfield, IL 62703
Owner Status:
Current Owner
Purchase Date:
6/1/1999
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
7/12/2011
Motor Fuel Dispensing Permits
No MFD Permits Found
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0028950
Curry Ready Mix & Builders Supply
Current Owner
6/1/1999
U0009220
Lippold & Arnett, Inc.
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
10-0527
5/19/2010
Removal Log
00538-2010REM
14-0073
1/21/2014
Removal Log
01288-2013REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
99-1004
Eligible
5/20/1999
6/7/1999
$15,000
14-0073
Returned
3/20/2014
4/17/2014
$Not Selected
14-0073
Eligible
9/6/2016
9/7/2016
$5,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
12000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/21/2014
OSFM
First Notify Date:
3/23/1988
Abandoned Material:
Current Age:
25
Abandoned Date:
Install Date:
5/1/1988
Red Tag Issue Date:
Last Used Date:
6/23/2011
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
7/28/2010
7/28/2013
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
6/30/2010
6/30/2013
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/8/2010
7/8/2011
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Flex Connector Steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
STIP3 Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
1000
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Heating Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
State
Removed Date:
5/19/2010
OSFM
First Notify Date:
4/7/1995
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
8/1/1988
Red Tag Issue Date:
Last Used Date:
10/20/2006
Fee Due:
$0.00
Product Date:
8/1/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
110 - 600 gallons Manual Tank Gauging
N/A
N/A
Overfill Prev Device
Less than 25 gallon fills
N/A
N/A
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed less than 25 gallon fills
N/A
N/A
Tank
Steel Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
15000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/21/2014
OSFM
First Notify Date:
9/23/1999
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
11/16/1999
Red Tag Issue Date:
Last Used Date:
6/23/2011
Fee Due:
$0.00
Product Date:
11/16/1999
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/8/2010
7/8/2011
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300c
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found