Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5009704
Status: Active
Facility Name: Country General, Inc.
Address: 204 North Adams Street Manito, IL 61546
County: Mason
Property Parcel:
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: AA00511
Green Tag Issue Date: 2/10/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service; Unattended Self Service

Owner Details

Owner Name: Country General, Inc.
Owner Address: P.O. Box 619/ 204-206 N. Adams Manito, IL 61546
Owner Status: Current Owner
Purchase Date: 1/1/1973
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/28/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0014974 Country General, Inc. Current Owner 1/1/1973

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 41 Abandoned Date: 3/11/1999
Install Date: Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 41 Abandoned Date: 3/11/1999
Install Date: Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material: Unknown
Current Age: 32 Abandoned Date: 3/11/1999
Install Date: Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/3/1999 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/15/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/15/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/27/2026 1/27/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 1/27/2026 1/27/2027
Overfill Prev Device Overfill Drop Tube Valve 1/29/2025 1/29/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/29/2025 1/29/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 1/27/2026



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/3/1999 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/15/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/15/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/27/2026 1/27/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 1/27/2026 1/27/2027
Overfill Prev Device Overfill Drop Tube Valve 1/29/2025 1/29/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/29/2025 1/29/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 1/27/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found