Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5008102
Status: Active
Facility Name: PH Fast Stop
Address: 701 W. Quincy Street Pleasant Hill, IL 62366
County: Pike
Property Parcel: 74-025-012
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000782
Green Tag Issue Date: 7/27/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Arisha Enterprises, Inc.
Owner Address: 701 W. Quincy Street Pleasant Hill, IL 62366
Owner Status: Current Owner
Purchase Date: 7/22/2025
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/27/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041554 Arisha Enterprises, Inc. Current Owner 7/22/2025
U0034315 PH Petroleum, LLC Former Owner 8/14/2007
U0033689 P & B Petroleum, Inc. Former Owner 2/5/2006
U0030686 Hoaglin Convenience Stores, Inc. Former Owner 5/1/2002
U0012222 Puckett Oil Co. Former Owner 4/1/1990
U0010017 Mckinnon Sonny Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251751 (Pending)    Issue Date: 7/10/2025    Expiration Date: 9/8/2025    View NOV Form

Tanks Violations
1, 5, 6 Overfill prevention equipment inspection(s) not completed (Required every 3 years).
5, 6 Tank sacrificial anode system not tested (Required every 3 years).

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
95-1924 Eligible 11/18/1997 12/3/1997 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/6/1987 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 7/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/5/2024 9/5/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 9/5/2024 9/5/2025
Overfill Prev Device Overfill Alarm 8/25/2022 8/25/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/7/2022 2/7/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/5/2024



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/24/1996
OSFM First Notify Date: 7/6/1987 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: 9/10/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/24/1996
OSFM First Notify Date: 7/6/1987 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: 9/10/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/24/1996
OSFM First Notify Date: 7/6/1987 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: 9/10/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/19/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 6/1/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 12/21/2020 12/21/2023
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/5/2024 9/5/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 9/5/2024 9/5/2025
Overfill Prev Device Overfill Alarm 8/25/2022 8/25/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/7/2022 2/7/2025
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/5/2024



Tank Number 6

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/19/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 6/1/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 12/21/2020 12/21/2023
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/5/2024 9/5/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 9/5/2024 9/5/2025
Overfill Prev Device Overfill Alarm 8/25/2022 8/25/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/7/2022 2/7/2025
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/5/2024

Dispenser Information



Name\ID 1&2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3&4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5&6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found