Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5001140
Status: Active
Facility Name: Waverly Gas Mart, Inc.
Address: 405 W. Elm Street Waverly, IL 62692
County: Morgan
Property Parcel: 19-11-102-025
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01509
Green Tag Issue Date: 7/29/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Pawar R & F, Inc.
Owner Address: 1201 Woodridge Court Decatur, IL 62536
Owner Status: Current Owner
Purchase Date: 11/2/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/18/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041552 Pawar R & F, Inc. Current Owner 11/2/2023
U0039745 Ada Singh, LLC Former Owner 1/3/2020
U0039246 Fanning Fuel Co. Former Owner 4/10/2018
U0037571 Meera Shakti, Inc. / Meera, LLC Former Owner
U0037571 Meera Shakti, Inc. / Meera, LLC Former Owner
U0004981 Fanning Oil Company, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
90-1212 5/13/2013 Abandonment Log 00325-2013ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
90-1212 Eligible 6/11/1998 7/1/1998 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/6/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 36 Abandoned Date: 5/13/2013
Install Date: Red Tag Issue Date:
Last Used Date: 3/26/2013 Fee Due: $0.00
Product Date: 5/10/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/7/2013 1/7/2014
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/7/2013 1/7/2014
Corrosion Prot - Tank Lining Materials Internal 3/26/2013 3/26/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/3/2012 7/3/2013
Leak Detect - Tank Automatic Tank Gauging Gilbarco Tank Monitor 2
Overfill Prev Device Ball Float Vent Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/6/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 36 Abandoned Date: 5/13/2013
Install Date: Red Tag Issue Date:
Last Used Date: 3/26/2013 Fee Due: $0.00
Product Date: 5/10/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/7/2013 1/7/2014
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/7/2013 1/7/2014
Corrosion Prot - Tank Lining Materials Internal 3/26/2013 3/26/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/3/2012 7/3/2013
Leak Detect - Tank Automatic Tank Gauging Gilbarco Tank Monitor 2
Overfill Prev Device Ball Float Vent Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1990
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1990
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/15/1993 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 5/10/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/10/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/3/2025 6/3/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/3/2025 6/3/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/3/2025 6/3/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2025 6/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/3/2025 6/3/2026
Overfill Prev Device Ball Float Vent Valve 6/3/2025 6/3/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/3/2025 6/3/2028
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/3/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 6/3/2025



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/15/1993 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 5/10/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/10/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/3/2025 6/3/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/3/2025 6/3/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2025 6/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/3/2025 6/3/2026
Overfill Prev Device Ball Float Vent Valve 6/3/2025 6/3/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/3/2025 6/3/2028
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 8/4/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 6/3/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found