Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5000518
Status: Active
Facility Name: Morgan County Highway Dept
Address: 651 Brooklyn PO Box 458 Jacksonville, IL 62651
County: Morgan
Property Parcel: 09-21-403-016
Facility Type: County
Owner Type: County
Green Tag Decal: Z003514
Green Tag Issue Date: 7/16/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Morgan County Highway Dept.
Owner Address: 651 Brooklyn Ave PO Box 458 Jacksonville, IL 62651
Owner Status: Current Owner
Purchase Date: 2/26/1985
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/1/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 7/16/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0010594 Morgan County Highway Dept. Current Owner 2/26/1985

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/10/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 4/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/6/2023 6/6/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/6/2023 6/6/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/10/2024 6/10/2025
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500 6/10/2024 6/10/2025
Overfill Prev Device Overfill Drop Tube Valve 6/24/2022 6/24/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/24/2022 6/24/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/10/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/5/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 4/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/6/2023 6/6/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/6/2023 6/6/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500 6/10/2024 6/10/2025
Overfill Prev Device Overfill Drop Tube Valve 6/24/2022 6/24/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/24/2022 6/24/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID Gasoline

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms