Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5000106
Status: Active
Facility Name: U J's
Address: 302 West Union Avenue Litchfield, IL 62056
County: Montgomery
Property Parcel: 10-33-356-009
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000649
Green Tag Issue Date: 11/16/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: U-J's, Inc.
Owner Address: 302 West Union Avenue Litchfield, IL 62056
Owner Status: Current Owner
Purchase Date: 12/18/2008
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 9/24/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/7/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035238 U-J's, Inc. Current Owner 12/18/2008
U0004080 Dickerson Petroleum Former Owner 4/11/1999

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252669 (Pending)    Issue Date: 10/8/2025    Expiration Date: 12/7/2025    View NOV Form

Tanks Violations
3, 4, 5 Line leak detection equipment in alarm or failed test, must repair or replace.
3, 4, 5 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
3, 4 Water in containment without required sensors – install cathodic protection on all exposed steel piping or make containment watertight. By 10/13/28, all containments must be watertight and any CP installed in containments must be removed.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
08-1595 10/29/2008 Removal Log 01042-2008REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
07-1608 Eligible 1/14/2008 1/30/2008 $10,000
09-0903 Eligible 12/3/2009 1/15/2010 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/29/2008
OSFM First Notify Date: 12/30/1985 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 4/30/1984 Red Tag Issue Date:
Last Used Date: 12/13/2006 Fee Due: $0.00
Product Date: 4/30/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Tank Automatic Tank Gauging Incon TS 750

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/29/2008
OSFM First Notify Date: 12/30/1985 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 4/30/1984 Red Tag Issue Date:
Last Used Date: 10/17/2008 Fee Due: $0.00
Product Date: 4/30/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 12/18/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/18/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2025 6/3/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/3/2025 6/3/2026
Overfill Prev Device Overfill Drop Tube Valve 1/31/2023 1/31/2026
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 1/31/2023 1/31/2026
Leak Detect - Piping Sump Sensor 6/3/2025 6/3/2026
Spill Contain Device Single Wall Spill Bucket 1/31/2023 1/31/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 6/3/2025



Tank Number 4

Capacity: 13000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 12/18/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/18/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2025 6/3/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/3/2025 6/3/2026
Overfill Prev Device Overfill Drop Tube Valve 1/31/2023 1/31/2026
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 1/31/2023 1/31/2026
Leak Detect - Piping Non-Discriminating Sump Sensor 1/31/2023 1/31/2024
Leak Detect - Piping Sump Sensor 6/3/2025 6/3/2026
Spill Contain Device Single Wall Spill Bucket 1/31/2023 1/31/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 6/3/2025



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 12/18/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/18/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2025 6/3/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/3/2025 6/3/2026
Overfill Prev Device Overfill Drop Tube Valve 1/31/2023 1/31/2026
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 1/31/2023 1/31/2026
Leak Detect - Piping Sump Sensor 6/3/2025 6/3/2026
Spill Contain Device Single Wall Spill Bucket 1/31/2023 1/31/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 6/3/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2023 1/31/2026
Leak Detect - Piping Sump Sensor 6/3/2025 6/3/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2023 1/31/2026
Leak Detect - Piping Sump Sensor 6/3/2025 6/3/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2023 1/31/2026
Leak Detect - Piping Sump Sensor 6/3/2025 6/3/2026

MFD Motorfuel Dispensing Forms