Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4047560
Status: Active
Facility Name: QT #7194
Address: 1505 N Neil Street
Champaign, IL 61821
County: Champaign
Property Parcel: 41-20-01-401-036
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z003622
Green Tag Issue Date: 3/5/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: QuikTrip Corporation
Owner Address: 4705 South 129th East Ave.
Tulsa, OK 74134
Owner Status: Current Owner
Purchase Date: 8/23/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/11/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/5/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034559 QuikTrip Corporation Current Owner 8/23/2021

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/5/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/22/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/21/2024 2/21/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 2/15/2024 2/15/2025
Overfill Prev Device Overfill Drop Tube Valve 2/5/2024 2/5/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Piping Single Wall Transition Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Spill Contain Device Double Wall Spill Bucket 10/26/2023 10/26/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/21/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/21/2024



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/5/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/22/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/21/2024 2/21/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 2/15/2024 2/15/2025
Overfill Prev Device Overfill Drop Tube Valve 2/5/2024 2/5/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Piping Single Wall Transition Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Spill Contain Device Double Wall Spill Bucket 10/26/2023 10/26/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/21/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/21/2024



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/5/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/22/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/21/2024 2/21/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 2/15/2024 2/15/2025
Overfill Prev Device Overfill Drop Tube Valve 2/5/2024 2/5/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Piping Single Wall Transition Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Spill Contain Device Double Wall Spill Bucket 10/26/2023 10/26/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/21/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/21/2024



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/5/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/22/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/21/2024 2/21/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 2/15/2024 2/15/2025
Overfill Prev Device Overfill Drop Tube Valve 2/5/2024 2/5/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Piping Single Wall Transition Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Spill Contain Device Double Wall Spill Bucket 10/26/2023 10/26/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/21/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/21/2024



Tank Number 5

Capacity: 18000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/5/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/29/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/21/2024 2/21/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 2/15/2024 2/15/2025
Overfill Prev Device Overfill Drop Tube Valve 2/5/2024 2/5/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Piping Single Wall Transition Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Spill Contain Device Double Wall Spill Bucket 10/26/2023 10/26/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/21/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/21/2024



Tank Number 6

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/5/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/29/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/15/2024 2/15/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 2/15/2024 2/15/2025
Overfill Prev Device Overfill Drop Tube Valve 2/5/2024 2/5/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Piping Single Wall Transition Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Spill Contain Device Double Wall Spill Bucket 10/26/2023 10/26/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/21/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/21/2024



Tank Number 7

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/5/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/29/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/15/2024 2/15/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 2/15/2024 2/15/2025
Overfill Prev Device Overfill Drop Tube Valve 2/5/2024 2/5/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Piping Single Wall Transition Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Spill Contain Device Double Wall Spill Bucket 10/26/2023 10/26/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/21/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/21/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 1M/2M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 2S/3M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 3S/4M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 4S/5M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 5S/6M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/26/2023 10/26/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
4047560 QT #7194 Champaign 02/03/2024 Letter Form