Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4039784
Status: Active
Facility Name: Bp
Address: 104 US Route 51 Forsyth, IL 62535
County: Macon
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01037
Green Tag Issue Date: 5/23/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Narayana, LLC
Owner Address: 104 S. Route 51 Forsyth, IL 62535
Owner Status: Current Owner
Purchase Date: 1/23/2026
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/3/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041779 Narayana, LLC Current Owner 1/23/2026
U0037910 AZ SPE, LLC Former Owner 7/1/2015
U0037905 AZ, Inc. Former Owner 7/1/2015
U0038399 Singh, Harjinder Former Owner 2/13/2015
U0037490 SBJ Petroleum #2, LLC Former Owner 1/6/2012
U0034182 Sandhu-Decatur, LLC - Forsyth Former Owner 9/30/2006
U0029529 Forsyth C.C. Inc Former Owner 7/7/2000

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261182 (Pending)    Issue Date: 5/5/2026    Expiration Date: 7/4/2026    View NOV Form

Tanks Violations
1, 2, 3 Annual leak detection certification not completed (Required annually). - Expired 1/15/2026 and needs to be completed.
1, 2, 3 Line interstitial sensor functional test not accomplished (Required annually). - Expired 1/15/2026 and needs to be completed.
1, 2, 3 Triennial spill prevention equipment testing not completed. - Expired 3/24/2026 and needs to be completed.
1, 2, 3 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - Expired 3/24/2026 and needs to be completed.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 7/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/11/2026 5/11/2027
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD 5/11/2026 5/11/2027
Overfill Prev Device Ball Float Vent Valve OPW 53 5/11/2026 5/11/2029
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027
Spill Contain Device Single Wall Spill Bucket 5/11/2026 5/11/2029
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 5/11/2026



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 7/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/11/2026 5/11/2027
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD 5/11/2026 5/11/2027
Overfill Prev Device Ball Float Vent Valve OPW 53 5/11/2026 5/11/2029
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027
Spill Contain Device Single Wall Spill Bucket 5/11/2026 5/11/2029
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 5/11/2026



Tank Number 3

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 7/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/11/2026 5/11/2027
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD 5/11/2026 5/11/2027
Overfill Prev Device Overfill Drop Tube Valve 5/11/2026 5/11/2029
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027
Spill Contain Device Single Wall Spill Bucket 5/11/2026 5/11/2029
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 5/11/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027



Name\ID Abandon South East

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027



Name\ID Abandon South West

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/11/2026 5/11/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/11/2026 5/11/2027

MFD Motorfuel Dispensing Forms

No Forms Found