Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4034108
Status: Active
Facility Name: Circle K #1438
Address: 3604 North Mattis
Champaign, IL 61822
County: Champaign
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003102
Green Tag Issue Date: 12/7/2022
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100
Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 10/10/2014
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/24/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/7/2022 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 10/10/2014
U0013268 Tri-Star Marketing, Inc. Former Owner 9/27/1997
U0024033 Champaign Travel Plaza Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020241984 (Pending)    Issue Date: 7/16/2024    Expiration Date: 9/14/2024    View NOV Form

Tanks Violation
1, 3 Drop tube valve or overfill alarm failed inspection. Repair or replace equipment.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/11/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 7/6/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/6/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/24/2025 2/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/24/2025 2/24/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/24/2025 2/24/2026
Overfill Prev Device Overfill Drop Tube Valve 7/6/2021 3/19/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 11/14/2024 11/14/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 8/1/2019 8/1/2020
Leak Detect - Piping Sump Sensor with positive shutdown 2/24/2025 2/24/2026
Spill Contain Device Double Wall Spill Bucket 3/19/2024 3/19/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/24/2025



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/11/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 7/6/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/6/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/24/2025 2/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/24/2025 2/24/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/24/2025 2/24/2026
Overfill Prev Device Overfill Drop Tube Valve 3/19/2024 3/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 11/14/2024 11/14/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026
Spill Contain Device Double Wall Spill Bucket 6/25/2024 6/25/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/24/2025



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/27/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 11/15/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/16/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/24/2025 2/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/24/2025 2/24/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/24/2025 2/24/2026
Overfill Prev Device Overfill Drop Tube Valve 5/25/2021 3/19/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026
Spill Contain Device Single Wall Spill Bucket 3/19/2024 3/19/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/24/2025



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/13/2011 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 11/15/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/24/2025 2/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/24/2025 2/24/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/24/2025 2/24/2026
Overfill Prev Device Overfill Drop Tube Valve 3/19/2024 3/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026
Spill Contain Device Double Wall Spill Bucket 3/19/2024 3/19/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/24/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 21M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/14/2024 11/14/2027
Leak Detect - Piping Sump Sensor with positive shutdown 2/24/2025 2/24/2026



Name\ID 21S/22M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/14/2024 11/14/2027
Leak Detect - Piping Sump Sensor with positive shutdown 2/24/2025 2/24/2026



Name\ID 22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/11/2020 5/11/2023
Leak Detect - Piping Sump Sensor with positive shutdown 2/24/2025 2/24/2026



Name\ID 22S/23M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/14/2024 11/14/2027
Leak Detect - Piping Sump Sensor with positive shutdown 2/24/2025 2/24/2026



Name\ID 23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/11/2020 5/11/2023
Leak Detect - Piping Sump Sensor with positive shutdown 2/24/2025 2/24/2026



Name\ID 23S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/14/2024 11/14/2027
Leak Detect - Piping Sump Sensor with positive shutdown 2/24/2025 2/24/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/27/2024 8/27/2027
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026

MFD Motorfuel Dispensing Forms

No Forms Found