Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
4032125
Status:
Active
Facility Name:
Casey's General Store #1766
Address:
1671 South Taylorville Road Decatur, IL 62521
County:
Macon
Property Parcel:
04-12-21-403-006
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Y000801
Green Tag Issue Date:
1/3/2023
Green Tag Expiration Date:
12/31/2025
Owner Details
Owner Name:
Casey's Retail Company
Owner Address:
3305 SE Delaware Ave. P.O. Box 3004 Ankeny, IA 50021
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
1/29/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
1/3/2023
12/31/2025
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0002560
Casey's Retail Company
Current Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
01065-2025UPG
Upgrade
Approved / Issued
8/15/2025
8/15/2025
2/18/2026
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/25/1994
Abandoned Material:
Current Age:
31
Abandoned Date:
Install Date:
4/1/1994
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
4/1/1994
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
2/5/2025
2/5/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
2/5/2025
2/5/2026
Overfill Prev Device
Overfill Drop Tube Valve
2/7/2024
2/7/2027
Piping
Flexible Double Wall A.P.T. Poly Tech
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
2/7/2024
2/7/2027
Leak Detect - Piping
Sump Sensor
2/5/2025
2/5/2026
Spill Contain Device
Single Wall Spill Bucket
2/7/2024
2/7/2027
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall A.P.T. Poly Tech
Precision Test (Piping)
Pass
1/10/2020
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/25/1994
Abandoned Material:
Current Age:
31
Abandoned Date:
Install Date:
4/1/1994
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
4/1/1994
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
2/5/2025
2/5/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
2/5/2025
2/5/2026
Overfill Prev Device
Overfill Drop Tube Valve
2/7/2024
2/7/2027
Piping
Flexible Double Wall A.P.T. Poly Tech
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
2/7/2024
2/7/2027
Leak Detect - Piping
Sump Sensor
2/7/2024
2/5/2025
Leak Detect - Piping
Sump Sensor with positive shutdown
8/14/2025
8/14/2026
Spill Contain Device
Single Wall Spill Bucket
2/7/2024
2/7/2027
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall A.P.T. Poly Tech
Precision Test (Piping)
Pass
1/10/2020
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/7/2024
2/7/2027
Leak Detect - Piping
Sump Sensor
2/5/2025
2/5/2026
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/7/2024
2/7/2027
Leak Detect - Piping
Sump Sensor
2/5/2025
2/5/2026
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/7/2024
2/7/2027
Leak Detect - Piping
Sump Sensor
2/5/2025
2/5/2026
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/7/2024
2/7/2027
Leak Detect - Piping
Sump Sensor
2/5/2025
2/5/2026
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/7/2024
2/7/2027
Leak Detect - Piping
Sump Sensor
2/5/2025
2/5/2026
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/7/2024
2/7/2027
Leak Detect - Piping
Sump Sensor
2/5/2025
2/5/2026
MFD
Motorfuel Dispensing Forms
No Forms Found