Facility Details
Facility Number:
4032027
Status:
Active
Facility Name:
Casey's #1721
Address:
3007 Gill Street Bloomington, IL 61702
County:
McLean
Property Parcel:
14-36-227-015
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA00977
Green Tag Issue Date:
2/6/2025
Green Tag Expire Date:
12/31/2027
MFD Type:
Self Service
Owner Details
Owner Name:
Casey's Retail Company
Owner Address:
3305 SE Delaware Ave. P.O. Box 3004 Ankeny, IA 50021
Owner Status:
Current Owner
Purchase Date:
11/1/1993
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
1/29/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0002560
Casey's Retail Company
Current Owner
11/1/1993
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00193-2026CAT
Cathodic Protection
Approved / Issued
2/18/2026
2/18/2026
8/18/2026
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/30/1993
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
11/1/1993
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/2/1993
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
8/12/2025
8/12/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
8/12/2025
8/12/2026
Overfill Prev Device
Overfill Drop Tube Valve
9/21/2023
9/21/2026
Piping
Flex Connector Steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
9/21/2023
9/21/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
1/4/2021
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/30/1993
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
11/1/1993
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/2/1993
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
8/12/2025
8/12/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
8/12/2025
8/12/2026
Overfill Prev Device
Overfill Drop Tube Valve
9/21/2023
9/21/2026
Piping
Flex Connector Steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
9/21/2023
9/21/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
14000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Does Not Exist
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Does Not Exist
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
8000
Petroleum Use:
Product:
E85
CERCLA Substance:
Status:
Does Not Exist
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found