Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4024537
Status: Active
Facility Name: Marrackech Imports, Inc. d/b/a C & C's One Stop
Address: 2532 E. US Highway 36 Newman, IL 61942
County: Douglas
Property Parcel: 070631330010
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: AA00431
Green Tag Issue Date: 9/9/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service; Unattended Self Service

Owner Details

Owner Name: Marrakech Imports, Inc. d/b/a C & C's One Stop
Owner Address: 2532 E. U.S. Highway 36 Newman, IL 61942
Owner Status: Current Owner
Purchase Date: 8/1/2011
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 5/6/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036207 Marrakech Imports, Inc. d/b/a C & C's One Stop Current Owner 8/1/2011
U0007673 J & T One Stop, Inc. Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00208-2026INS Install Approved / Revised 2/20/2026 2/20/2026 8/20/2026 Documents
00190-2026REM Removal Approved / Issued 2/18/2026 2/18/2026 8/18/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2026-0126 3/4/2026 Removal Log 00190-2026REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/4/2026
OSFM First Notify Date: 10/17/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/3/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/4/2025 6/4/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 6/4/2025 6/4/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2025 6/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/4/2025 6/4/2026
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 6/4/2025



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/4/2026
OSFM First Notify Date: 10/17/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/3/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/4/2025 6/4/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 6/4/2025 6/4/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2025 6/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/4/2025 6/4/2026
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 6/4/2025



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/4/2026
OSFM First Notify Date: 10/17/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/3/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/4/2025 6/4/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 6/4/2025 6/4/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2025 6/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/4/2025 6/4/2026
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 6/4/2025



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/4/2026
OSFM First Notify Date: 10/17/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/9/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/4/2025 6/4/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 6/4/2025 6/4/2026
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/4/2025 6/4/2026
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/21/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 4/1/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2026 4/28/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/23/2026 4/23/2027
Overfill Prev Device Overfill Drop Tube Valve 4/9/2026 4/9/2029
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/9/2026 4/9/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/23/2026 4/23/2027
Spill Contain Device Double Wall Spill Bucket 4/9/2026 4/9/2029
Tank Composite Double Wall Permatank N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/28/2026
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 4/28/2026



Tank Number 6

Capacity: 3000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/21/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 4/1/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2026 4/28/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/23/2026 4/23/2027
Overfill Prev Device Overfill Drop Tube Valve 4/9/2026 4/9/2029
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/9/2026 4/9/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/23/2026 4/23/2027
Spill Contain Device Double Wall Spill Bucket 4/9/2026 4/9/2029
Tank Composite Double Wall Permatank N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/28/2026
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 4/28/2026



Tank Number 7

Capacity: 3000 Petroleum Use: Dispensing
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/21/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 4/1/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2026 4/28/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/23/2026 4/23/2027
Overfill Prev Device Overfill Drop Tube Valve 4/9/2026 4/9/2029
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/9/2026 4/9/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/23/2026 4/23/2027
Spill Contain Device Double Wall Spill Bucket 4/9/2026 4/9/2029
Tank Composite Double Wall Permatank N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/28/2026
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 4/28/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/9/2026 4/9/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/23/2026 4/23/2027

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
4024537 Marrackech Imports, Inc. d/b/a C & C's One Stop Newman 02/20/2026 Letter Form