Facility Details
Facility Number:
4021216
Status:
Closed
Facility Name:
former Petro Junction
Address:
405 S. 6th Street Marshall, IL 62441
County:
Clark
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
M002774
Green Tag Issue Date:
5/6/2011
Green Tag Expire Date:
12/31/2013
MFD Type:
N/A
Owner Details
Owner Name:
Ron Stone
Owner Address:
17896 N. Oakridge Avenue Marshall, IL 62441
Owner Status:
Current Owner
Purchase Date:
8/14/2017
Type of Financial Responsibility:
Commercial Insurance and Designated Savings Account
Financial Responsibility Reporting Due Date:
12/21/2019
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0038893
Stone, Ron
Current Owner
8/14/2017
U0014644
Strohm Oil Company, Inc.
Former Owner
6/24/2009
U0014644
Strohm Oil Company, Inc.
Former Owner
U0035362
Ward, Timothy
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
02-1499
12/17/2002
Removal Log
01913-2002REM
19-0979
10/8/2019
Removal Log
01856-2019REM
19-0979
10/9/2019
Removal Log
01856-2019REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
02-1499
Eligible
3/25/2003
3/25/2003
$15,000
20190979
Eligible
10/31/2019
10/31/2019
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/17/2002
OSFM
First Notify Date:
5/7/1986
Abandoned Material:
Current Age:
42
Abandoned Date:
Install Date:
1/1/1960
Red Tag Issue Date:
Last Used Date:
9/19/2008
Fee Due:
$0.00
Product Date:
1/1/1960
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
5000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/17/2002
OSFM
First Notify Date:
5/7/1986
Abandoned Material:
Current Age:
42
Abandoned Date:
Install Date:
1/1/1960
Red Tag Issue Date:
Last Used Date:
11/8/2002
Fee Due:
$0.00
Product Date:
1/1/1960
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
2000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/17/2002
OSFM
First Notify Date:
5/7/1986
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
1/1/1975
Red Tag Issue Date:
Last Used Date:
11/8/2002
Fee Due:
$0.00
Product Date:
1/1/1975
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
2000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/17/2002
OSFM
First Notify Date:
5/7/1986
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
1/1/1981
Red Tag Issue Date:
Last Used Date:
11/8/2002
Fee Due:
$0.00
Product Date:
1/1/1981
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
2000
Petroleum Use:
Product:
Kerosene
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/17/2002
OSFM
First Notify Date:
5/7/1986
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
1/1/1981
Red Tag Issue Date:
Last Used Date:
11/8/2002
Fee Due:
$0.00
Product Date:
1/1/1981
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
550
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/17/2002
OSFM
First Notify Date:
5/7/1986
Abandoned Material:
Current Age:
42
Abandoned Date:
Install Date:
1/1/1960
Red Tag Issue Date:
Last Used Date:
12/21/1998
Fee Due:
$0.00
Product Date:
1/1/1960
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/8/2019
OSFM
First Notify Date:
2/24/2003
Abandoned Material:
Current Age:
16
Abandoned Date:
Install Date:
1/7/2003
Red Tag Issue Date:
Last Used Date:
10/21/2011
Fee Due:
$0.00
Product Date:
1/7/2003
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Composite Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/20/2010
7/20/2011
Leak Detect - Piping
Sump Sensor
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Flexible Double Wall Total Containment Enviroflex non-corrosive
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Composite Double Wall Modern Welding Glasteel II
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
Sensor Functional
Pass
7/20/2010
Leak Detect - Piping
Sump Sensor
Sensor Functional
Pass
7/20/2010
Tank Number 8
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/8/2019
OSFM
First Notify Date:
2/24/2003
Abandoned Material:
Current Age:
16
Abandoned Date:
Install Date:
1/7/2003
Red Tag Issue Date:
Last Used Date:
10/21/2011
Fee Due:
$0.00
Product Date:
1/7/2003
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Composite Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/20/2010
7/20/2011
Leak Detect - Piping
Sump Sensor
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Flexible Double Wall Total Containment Enviroflex non-corrosive
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Composite Double Wall Modern Welding Glasteel II
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
Sensor Functional
Pass
7/20/2010
Leak Detect - Piping
Sump Sensor
Sensor Functional
Pass
7/20/2010
Tank Number 9
Capacity:
1000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/2019
OSFM
First Notify Date:
2/24/2003
Abandoned Material:
Current Age:
16
Abandoned Date:
Install Date:
1/7/2003
Red Tag Issue Date:
Last Used Date:
10/21/2011
Fee Due:
$0.00
Product Date:
1/7/2003
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Composite Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/20/2010
7/20/2011
Leak Detect - Piping
Sump Sensor
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Flexible Double Wall Total Containment Enviroflex non-corrosive
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Composite Double Wall Modern Welding Glasteel II
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
Sensor Functional
Pass
7/20/2010
Leak Detect - Piping
Sump Sensor
Sensor Functional
Pass
7/20/2010
Tank Number 10
Capacity:
550
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/17/2002
OSFM
First Notify Date:
12/20/2002
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
1/1/1979
Red Tag Issue Date:
Last Used Date:
12/31/1979
Fee Due:
$0.00
Product Date:
1/1/1979
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found