Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0002560 |
Casey's Retail Company |
Current Owner |
11/15/2010 |
| U0006490 |
Harper Oil Company |
Former Owner |
8/21/1998 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 982055 |
8/18/1998 |
Removal Log |
1998-98 |
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/18/1998 |
|
OSFM
First Notify Date: |
5/6/1986 |
|
Abandoned Material: |
|
| Current Age: |
22 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/18/1998 |
|
OSFM
First Notify Date: |
5/6/1986 |
|
Abandoned Material: |
|
| Current Age: |
22 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/18/1998 |
|
OSFM
First Notify Date: |
5/6/1986 |
|
Abandoned Material: |
|
| Current Age: |
22 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/18/1998 |
|
OSFM
First Notify Date: |
5/6/1986 |
|
Abandoned Material: |
|
| Current Age: |
20 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
3/4/1999 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
8/21/1998 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/21/1998 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
3/11/2026 |
3/11/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
3/11/2026 |
3/11/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/2/2024 |
10/2/2027 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/2/2024 |
10/2/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/2/2024 |
10/2/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/2/2024 |
10/2/2027 |
|
Tank
|
Composite Double Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC
|
Precision Test (Piping)
|
Pass
|
10/12/2021
|
|
Tank
|
Composite Double Wall
|
Precision Test (Tank)
|
Pass
|
10/12/2021
|
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors
|
Sensor Functional
|
Pass
|
8/20/2009
|
|
Leak Detect - Piping
|
Non-Discriminating Sump Sensor
|
Sensor Functional
|
Pass
|
8/20/2009
|
Tank Number 6
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
3/4/1999 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
8/21/1998 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/21/1998 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
3/11/2026 |
3/11/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
3/11/2026 |
3/11/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/2/2024 |
10/2/2027 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/2/2024 |
10/2/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/2/2024 |
10/2/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/2/2024 |
10/2/2027 |
|
Tank
|
Composite Double Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC
|
Precision Test (Piping)
|
Pass
|
10/12/2021
|
|
Tank
|
Composite Double Wall
|
Precision Test (Tank)
|
Pass
|
10/12/2021
|
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors
|
Sensor Functional
|
Pass
|
8/20/2009
|
|
Leak Detect - Piping
|
Non-Discriminating Sump Sensor
|
Sensor Functional
|
Pass
|
8/20/2009
|
Tank Number 7
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
3/4/1999 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
8/21/1998 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/21/1998 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
3/11/2026 |
3/11/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
3/11/2026 |
3/11/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/2/2024 |
10/2/2027 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/2/2024 |
10/2/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/2/2024 |
10/2/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/2/2024 |
10/2/2027 |
|
Tank
|
Composite Double Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC
|
Precision Test (Piping)
|
Pass
|
10/12/2021
|
|
Tank
|
Composite Double Wall
|
Precision Test (Tank)
|
Pass
|
10/12/2021
|
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors
|
Sensor Functional
|
Pass
|
8/20/2009
|
|
Leak Detect - Piping
|
Non-Discriminating Sump Sensor
|
Sensor Functional
|
Pass
|
8/20/2009
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found